2004
DOI: 10.1016/j.athoracsur.2003.10.010
|View full text |Cite
|
Sign up to set email alerts
|

Continuous measurement of oxygen consumption during cardiopulmonary bypass: description of the method and in vivo observations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
4
0

Year Published

2005
2005
2022
2022

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 20 publications
1
4
0
Order By: Relevance
“…Our study, based on the continuous measurement of VO 2 , demonstrates that the major component of the increase in arterial lactate levels and VO 2 during rewarming was occurring during this brief period. The acute increase in VO 2 , which we have previously described, 10 was accompanied by an acute increase in lactate. In fact, the immediate post-ACC release period is the only period that lactate levels increased significantly and accounted for 68% of the total increase during the entire rewarming period.…”
Section: Discussionsupporting
confidence: 63%
See 3 more Smart Citations
“…Our study, based on the continuous measurement of VO 2 , demonstrates that the major component of the increase in arterial lactate levels and VO 2 during rewarming was occurring during this brief period. The acute increase in VO 2 , which we have previously described, 10 was accompanied by an acute increase in lactate. In fact, the immediate post-ACC release period is the only period that lactate levels increased significantly and accounted for 68% of the total increase during the entire rewarming period.…”
Section: Discussionsupporting
confidence: 63%
“…Indeed, in our previous study with the same protocol and technique, we found a significant underestimation of VO 2 calculated from the reversed Fick from the pump flow and arterial and venous oxygen contents as compared to the directly measured VO 2 . 10 Thus, ERO 2 derived in our study may be overestimated. Nonetheless, using the independent measurements of VO 2 and DO 2 avoids the problem of mathematical coupling when DO 2 is derived from VO 2 .…”
Section: Limitationsmentioning
confidence: 56%
See 2 more Smart Citations
“…We have adapted the method to continuously measure VO 2 with a variety of pediatric ventilators and anesthesia ventilators before, during, and after CPB, using the AMIS 2000 Medical Respiratory Mass Spectrometer System (Innovision A/C Odense, Denmark). Our combination of techniques and equipment makes respiratory mass spectrometry a unique and powerful tool in multiple settings: in the cardiac catheterization laboratory (SchulzeNeick, Li et al 2002 ;, in the operating room (Li, Stokoe et al 2004), and in the ICU (Li, Hoschtitzky et al 2004;Li, Schulze-Neick et al 2000;Schulze-Neick, Li et al 2001).…”
Section: Direct Measurement Of Vo 2 Using Respiratory Mass Spectrometrymentioning
confidence: 99%