1984
DOI: 10.1161/01.cir.70.5.812
|View full text |Cite
|
Sign up to set email alerts
|

Continuous measurement of left ventricular volume in animals and humans by conductance catheter.

Abstract: An eight-electrode conductance catheter previously developed by us and used to determine stroke volume in dogs was applied in human beings and dogs to measure absolute left ventricular volume quantitatively. For calibration we developed the formula V(t) = (l/a)(L2/Yb)G(t) -

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

6
564
1
4

Year Published

1998
1998
2008
2008

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 847 publications
(575 citation statements)
references
References 13 publications
6
564
1
4
Order By: Relevance
“…The catheter provided simultaneous proximal aortic and ventricular cavity micromanometer pressures and chamber volume, the latter by conductance method. 7,8 Catheter volume was calibrated by matching to steady-state echo-derived end-diastolic and end-systolic dimensions (Simpson's method).…”
Section: Catheterization Protocolmentioning
confidence: 99%
“…The catheter provided simultaneous proximal aortic and ventricular cavity micromanometer pressures and chamber volume, the latter by conductance method. 7,8 Catheter volume was calibrated by matching to steady-state echo-derived end-diastolic and end-systolic dimensions (Simpson's method).…”
Section: Catheterization Protocolmentioning
confidence: 99%
“…11,12 In brief, saturated saline (1 to 2 mL) was rapidly injected into the main pulmonary artery to obtain the parallel conductance, the contribution of surrounding structures. The parallel conductance was repeatedly measured at the beginning of each protocol.…”
Section: Preparationmentioning
confidence: 99%
“…Difficulties include the need for a precise high-fidelity left ventricular (LV) volume curve as well as the need for multiple pressure-volume (P-V) loops under various loading conditions. Introduction of the conductance catheter 9,11,12 and of the concept of a hydromotive pressure source 13,14 for single-beat E es estimation has partly solved these difficulties. Mirsky et al 15,16 developed a single-beat method to assess myocardial contractility by fitting a model to late systolic data and estimating the unstressed state.…”
mentioning
confidence: 99%
“…Briefly, the catheter measured continuously the timevarying electrical conductance G(t) of the blood within the LV cavity of the beating heart [5,6]. Our custom-made signal conditioner-processor (SI Medicotech Co., Ltd., Osaka, Japan) converted the G(t) to LV conductance volume after calibrating blood conductivity in the sampling cuvette.…”
Section: Surgical Preparationmentioning
confidence: 99%
“…We obtained the parallel conductance Gp attributable to the conductance of the LV wall and the surrounding tissues and fluid by the standard hypertonic saline dilution method. From this Gp, we calculated a constant offset volume (Vc) and obtained the absolute LVV by subtracting Vc from the LV conductance volume [5,6].…”
Section: Surgical Preparationmentioning