2013
DOI: 10.3390/diagnostics3040385
|View full text |Cite
|
Sign up to set email alerts
|

Continuous Glucose Monitoring Systems: A Review

Abstract: There have been continuous advances in the field of glucose monitoring during the last four decades, which have led to the development of highly evolved blood glucose meters, non-invasive glucose monitoring (NGM) devices and continuous glucose monitoring systems (CGMS). Glucose monitoring is an integral part of diabetes management, and the maintenance of physiological blood glucose concentration is the only way for a diabetic to avoid life-threatening diabetic complications. CGMS have led to tremendous improve… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
121
0
3

Year Published

2016
2016
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 214 publications
(129 citation statements)
references
References 105 publications
(128 reference statements)
0
121
0
3
Order By: Relevance
“…Since it is only recently that any devices have even approached such performance, regulatory criteria for device approval have been more pragmatic, focusing on the hazards of incorrect readings (e.g., suboptimal treatment decisions, including improper adjustments in medication dosage, potentially increasing the frequency of both hypoglycemia and hyperglycemia) (58). Accuracy, ergonomics, and ease of use of blood glucose meters have improved dramatically over time (124)(125)(126), and the accuracy of CGM is beginning to approach that of BGM devices (113,114,(127)(128)(129)(130). However, a clinically significant variation in accuracy and precision persists among currently marketed GM devices.…”
Section: Gm Accuracy Precision and Data Display Metricsmentioning
confidence: 99%
“…Since it is only recently that any devices have even approached such performance, regulatory criteria for device approval have been more pragmatic, focusing on the hazards of incorrect readings (e.g., suboptimal treatment decisions, including improper adjustments in medication dosage, potentially increasing the frequency of both hypoglycemia and hyperglycemia) (58). Accuracy, ergonomics, and ease of use of blood glucose meters have improved dramatically over time (124)(125)(126), and the accuracy of CGM is beginning to approach that of BGM devices (113,114,(127)(128)(129)(130). However, a clinically significant variation in accuracy and precision persists among currently marketed GM devices.…”
Section: Gm Accuracy Precision and Data Display Metricsmentioning
confidence: 99%
“…As the presented case illustrate, this lack of consistent patterns and complexity of glycemic management results in poor glycemic control and recurrent DKA even in motivated patients. Thus, to break this vicious cycle and to address complexities of glycemic management of DM1 the logical future solution is to engage machine learning and artificial intelligence, facilitated by continuous real-time glucose monitoring, and development of closed-loop glucose management systems for women of childbearing age [12].…”
Section: Discussionmentioning
confidence: 99%
“…Limb threatening signs of diabetic foot include cellulitis of greater than 2 cm, lymphangitis, odour from wound, edema, ischemic changes and signs of systemic toxicity. Hospital admission should be considered and if the wound fails to heal, foot sparing reconstructive procedures should be addressed [27][28][29][30][31][32][33].…”
Section: Discussionmentioning