1985
DOI: 10.1093/bja/57.3.264
|View full text |Cite
|
Sign up to set email alerts
|

Continuous Extradural Infusion of 0.0625% or 0.125% Bupivacaine for Pain Relief in Primigravid Labour

Abstract: The efficacy of an extradural infusion of 0.0625% or 0.125% bupivacaine was studied in 98 primigravid mothers in active labour. No special measures were taken to posture the mother (except to avoid aorto-caval compression). The study regimen included a control group (no infusion) receiving intermittent top-ups (0.25%. bupivacaine 8-10 ml), two groups receiving bupivacaine 6.25 mg h-1 infusion in different concentrations (0.0625% and 0.125%), a fourth group receiving 0.125% bupivacaine 12.5 mg h-1 infusion, and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
11
0

Year Published

1988
1988
2015
2015

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 61 publications
(12 citation statements)
references
References 14 publications
1
11
0
Order By: Relevance
“…The continuous infusion of local anaesthetic for extradural analgesia uses more local anaesthetic than the intermittent top-up technique [7,8]. As plasma concentrations at delivery were not significantly greater, these findings suggest differences in drug uptake and distribution between the two types of administration [7,9].…”
Section: Discussionmentioning
confidence: 91%
“…The continuous infusion of local anaesthetic for extradural analgesia uses more local anaesthetic than the intermittent top-up technique [7,8]. As plasma concentrations at delivery were not significantly greater, these findings suggest differences in drug uptake and distribution between the two types of administration [7,9].…”
Section: Discussionmentioning
confidence: 91%
“…8 Li et al studied the efficacy of bupivacaine by reducing the concentration from 0.25% down to 0.0625% as bolus. 9 Purdy et al compared 0.5%, 0.375% and 0.25% bupivacaine given as bolus doses. 10 They observed that by reducing the concentration, the quality of analgesia was not affected, and lower concentrations of local anaesthetics minimized or prevented the motor block.…”
Section: Discussionmentioning
confidence: 99%
“…Li et al studied the efficacy of bupivacaine by reducing the concentration from 0.25% upto 0.0625% as bolus. 11 Purdy et al compared 0.5%, 0.375%, 0.25% bupivacaine given as bolus. 12 They observed that by reducing the concentration, quality of analgesia did not differ.…”
Section: Combined Spinal Epidural Techniquementioning
confidence: 99%