2010 International Conference on Bioinformatics and Biomedical Technology 2010
DOI: 10.1109/icbbt.2010.5479013
|View full text |Cite
|
Sign up to set email alerts
|

Continuous cuffless blood pressure monitoring based on PTT

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 47 publications
(14 citation statements)
references
References 4 publications
0
12
0
1
Order By: Relevance
“…Shriram et al 20 have also examined using the PTT method as a means to estimate BP. Shriram used the Moens-Korteweg equation directly, the same as what has been described here in relation to Figure 4.…”
Section: Discussionmentioning
confidence: 99%
“…Shriram et al 20 have also examined using the PTT method as a means to estimate BP. Shriram used the Moens-Korteweg equation directly, the same as what has been described here in relation to Figure 4.…”
Section: Discussionmentioning
confidence: 99%
“…However, this method was also only designed to get blood pressure. There are many other researches on the blood pressure acquiring [5][6][7][8]. These methods are also only designed for blood pressure acquiring at the same time.…”
Section: Introductionmentioning
confidence: 98%
“…Continuous beat-to-beat measurements of BP obtained by the computation of the PTT from electrocardiography (ECG) and peripheral PPG signals however, are disputable for several reasons: (i) the dependency on the location and the distance of measurement points, (ii) the method used to find and interpret minima, maxima and saddle points within the PPG and ECG signals [5,6], (iii) the appearance of undetermined fluctuations in the time between the pressure wave and the ECG R-peak during blood ejection of the left ventricle [7] and (iv) the influences of auto-regulation on arterial stiffness that produce undetermined drifts of the PTT over time [8]. Nonetheless, the PTT method is subject of several publications that aim at a development of wearable continuous BPM devices [5,[9][10][11][12][13]. As PTT-based methods compute the BP by employing its correlation with the actual pulse wave velocity (PWV), the particular drawback of this approach is that PWV depends on the elasticity of the tested artery section, which in turn is considerably affected by a variety of physiological mechanisms of BP regulation.…”
Section: Introductionmentioning
confidence: 99%