2018
DOI: 10.1002/jbm.b.34137
|View full text |Cite
|
Sign up to set email alerts
|

Content of distinct metals in periprosthetic tissues and pseudosynovial joint fluid in patients with total joint arthroplasty

Abstract: This prospective study examined the content of metals released from total joint arthroplasty into joint fluid, whole blood and periprosthetic tissues. We determined the levels of Ti, V, Nb, Co, Cr, and Mo, using inductively coupled plasma mass spectrometry, in samples from patients who underwent reoperation of total hip or knee arthroplasty. All of the patients (n = 117) included in the study had either metal on polyethylene or ceramic on polyethylene-bearing pairs. First, our results conclusively showed that … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
15
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 11 publications
(20 citation statements)
references
References 30 publications
4
15
0
Order By: Relevance
“…For the experiments, we used Co(2+), Cr(3+) and Ni(2+) ions derived from metal salts. The tested concentrations were similar to those found in periprosthetic soft tissue [18] but lower than those reported for mineralized bone tissue [22]. The authors explained the relative high values in the mineralized bone tissue with the fact that the tissue was derived from the immediate vicinity, i.e., within a few millimeters, of the implant.…”
Section: Discussionsupporting
confidence: 70%
See 2 more Smart Citations
“…For the experiments, we used Co(2+), Cr(3+) and Ni(2+) ions derived from metal salts. The tested concentrations were similar to those found in periprosthetic soft tissue [18] but lower than those reported for mineralized bone tissue [22]. The authors explained the relative high values in the mineralized bone tissue with the fact that the tissue was derived from the immediate vicinity, i.e., within a few millimeters, of the implant.…”
Section: Discussionsupporting
confidence: 70%
“…Based on previous studies by Scharf et al (2014) and Drynda et al (2018) we used ion concentrations between 10 µM and 500 µM [6,23]. These concentrations correspond to 0.59–29.47 ppm Co and 0.52–26.00 ppm Cr and are similar to those reported in periprosthetic tissue by Kuba et al (2019) [18], but lower than those in bone tissue [22]. However, due to the analytical methodology it is difficult to specify whether the determined metal concentration originated from metal particles or metal ions.…”
Section: Introductionmentioning
confidence: 84%
See 1 more Smart Citation
“…The determination of Co, Cr, Ti and V in tissue samples was carried out by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) after microwave digestion with a mixture of HNO 3 and H 2 O 2 . The detailed measurement procedure including sample pretreatment and measures taken to assure quality of results is described in detail in our previous study 12 . A.…”
Section: Determination Of Metalsmentioning
confidence: 99%
“…Metals are released from all metallic implants by the mechanism of corrosion or tribocorrosion 7,10,11 . Several studies reported concentrations of selected metals in the periprosthetic tissues, joint fluid, or peripheral blood range [12][13][14][15] . The character of the tissue response to the presence of metals has been also studied [16][17][18] .…”
Section: Introductionmentioning
confidence: 99%