2022
DOI: 10.1109/jsen.2022.3174779
|View full text |Cite
|
Sign up to set email alerts
|

Contactless Monitoring of Heart Rate Variability During Respiratory Maneuvers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 53 publications
0
7
0
Order By: Relevance
“…This procedure turns out to be incomplete and misleading, since, in this way, the artifacts are averaged out, resulting in an overall better agreement. A recent study compared the PRV extracted from iPPG with the HRV obtained from ECG during a specific experimental protocol in a controlled setting, looking at the reliability of the PRV features [ 50 ]. In this study, we extracted the PRV signals from the UBFC-RPPG videos, and we investigated the reliability of PRV features by comparing them with the corresponding wearable PPG values.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…This procedure turns out to be incomplete and misleading, since, in this way, the artifacts are averaged out, resulting in an overall better agreement. A recent study compared the PRV extracted from iPPG with the HRV obtained from ECG during a specific experimental protocol in a controlled setting, looking at the reliability of the PRV features [ 50 ]. In this study, we extracted the PRV signals from the UBFC-RPPG videos, and we investigated the reliability of PRV features by comparing them with the corresponding wearable PPG values.…”
Section: Discussionmentioning
confidence: 99%
“…Bland–Altman quantifies the bias between the mean differences labeled as limits of agreement (LoA). The LoA was calculated as follows: where is the mean difference between the iPPG-based estimation and the finger clip PPG-based reference value, and SD is the standard deviation of the differences [ 50 ].…”
Section: Methodsmentioning
confidence: 99%
“…Widely used HRV time-domain indices [ 5 ] usually reflect the variations in inter-beat interval (IBI) between consecutive heartbeats in milliseconds (ms). A simple time-domain HRV metric, regularly used in comparative studies [ 6 ], is the root mean square (RMS) of the daily heartbeat intervals (beat-to-beat); it reflects the dynamic fluctuation range in heart rhythm [ 4 ].…”
Section: Methodsmentioning
confidence: 99%
“…Most patients with atrial fibrillation (AF) are unaware of its presence, i.e., asymptomatic. Additionally, as revealed by recent studies, defects in the autonomic nervous system (ANS), which involves the sympathetic, parasympathetic, and intrinsic neural networks, have been associated with the pathogenesis of AF [ 4 ], such abnormalities can be explored using heart rate variability (HRV) analysis on relatively long-term ECG recordings, by measuring the time intervals between heartbeats over a period of time, and it represents the equilibrium between the parasympathetic nervous system (PNS) and sympathetic nervous system (SNS) [ 5 , 6 ]. Early detection of AF onset could enable appropriate interventions, e.g., anticoagulation, aimed to reduce the risk of stroke.…”
Section: Introductionmentioning
confidence: 99%
“…For example, PPG can be integrated with the watch or the camera of a cell phone can measure the PPG signal as well. Furthermore, the non-contact PPG is also developing [32][33][34][35]. The PPG has the potential to be the health monitor in many situations.…”
Section: Fever Detection and Applicationmentioning
confidence: 99%