2011
DOI: 10.12693/aphyspola.119.783
|View full text |Cite
|
Sign up to set email alerts
|

Construction of Two-Axis Goniophotometer for Measurement of Spatial Distribution of a Light Source and Calculation of Luminous Flux

Abstract: A two-axis goniophotometer is constructed at National Metrology Institute of Turkey (TUBITAK UME) for characterizing photometric properties of compact light sources. With the new device, total luminous flux emitted by a light source at both cap-up or cap-down mounting positions is calculated from the integration of the illuminance values E(θ, ϕ) measured on the goniometric spherical surface. The internal calibration of the system is performed by means of two calibrated light sources with known luminous flux va… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0
1

Year Published

2013
2013
2017
2017

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 11 publications
0
5
0
1
Order By: Relevance
“…There are two methods of reproduction unit of luminous flux -photometric and goniophotometric [4][5].…”
Section: Methods Of the Reproduction Of The Luminous Fluxmentioning
confidence: 99%
“…There are two methods of reproduction unit of luminous flux -photometric and goniophotometric [4][5].…”
Section: Methods Of the Reproduction Of The Luminous Fluxmentioning
confidence: 99%
“…For an aperture considerably smaller than the laser beam lattice, the aperture area can now be obtained by combining Eqs. (4,5,6):…”
Section: Laser Scanning Methods For the Aperture Area Determinationmentioning
confidence: 99%
“…If an LED lamp is used as the external source, the PQED method can be used to measure its illuminance. Goniophotometers, on the other hand, determine the total luminous flux by measuring the illuminance of the light source at various solid angles [5,6]. The illuminance responsivity of the detector used in the goniophotometer can be calibrated against the PQED.…”
Section: Led Photometrymentioning
confidence: 99%
See 1 more Smart Citation
“…Для зменшення фонового освітлення фотометра перевідбитим від стін «чорної кімнати» світлом можна використовувати діафрагму, яка монтується на фотометр [4]. розкрив діафрагми обирається в залежності від співвідношення максимального розміру ОВ та відстані між центром обертання гоніометра та фотометром.…”
Section: рис 3 використані ов з відповідними кссunclassified