2015
DOI: 10.4028/www.scientific.net/amm.725-726.105
|View full text |Cite
|
Sign up to set email alerts
|

Construction of Temporary Accommodation Camp and Selection of Optimal Type of Building

Abstract: Surveys performed nationwide show that mobile temporary accommodation camps are being manufactured by more than 200 specialized enterprises (without considering the minor manufacturers) acting under different ministries and agencies. According to the analysis performed, today 26 basic mobile structural systems consisting of 18 conveyor-type and 8 demountable-type systems are being used on a national basis. Today national manufacturers are producing more than 250 types of container-type buildings and facilities… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 3 publications
0
1
0
Order By: Relevance
“…Before planning for the reconstruction of buildings and structures, it is necessary to carry out a competent examination of the technical condition [3]. According to regulatory documents, examination of the technical condition of buildings and structures is carried out at least once every 10 years and at least once every five years for buildings and structures or their individual elements operating in adverse conditions [4][5][6][7][8][9][10]. Based on the results of the survey, the actual bearing capacity and serviceability of building structures should be established in order to use these data in the development of a reinforcement project for reconstruction [11,12].…”
Section: Introductionmentioning
confidence: 99%
“…Before planning for the reconstruction of buildings and structures, it is necessary to carry out a competent examination of the technical condition [3]. According to regulatory documents, examination of the technical condition of buildings and structures is carried out at least once every 10 years and at least once every five years for buildings and structures or their individual elements operating in adverse conditions [4][5][6][7][8][9][10]. Based on the results of the survey, the actual bearing capacity and serviceability of building structures should be established in order to use these data in the development of a reinforcement project for reconstruction [11,12].…”
Section: Introductionmentioning
confidence: 99%