2011
DOI: 10.1016/j.talanta.2010.12.002
|View full text |Cite
|
Sign up to set email alerts
|

Construction of a new Cu2+ coated wire ion selective electrode based on 2-((2-(2-(2-(2-hydroxy-5-methoxybenzylidene amino)phenyl)disufanyl)phenylimino)methyl)-4-methoxyphenol Schiff base

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
14
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 46 publications
(15 citation statements)
references
References 55 publications
1
14
0
Order By: Relevance
“…[43][44][45][46][47][48][49][50][51] It can be concluded from the results in Table 4 that the potentiometric characteristics of this electrode are comparable with previously reported electrodes in most cases. The present sensor contains the advantages of simple operation, low cost, and fast response time.…”
Section: Discussionsupporting
confidence: 87%
See 1 more Smart Citation
“…[43][44][45][46][47][48][49][50][51] It can be concluded from the results in Table 4 that the potentiometric characteristics of this electrode are comparable with previously reported electrodes in most cases. The present sensor contains the advantages of simple operation, low cost, and fast response time.…”
Section: Discussionsupporting
confidence: 87%
“…Its wide industrial, agricultural, and domestic use has increased copper concentration in the environment. 1,2 On the other hand, copper is an essential element that is present in all organisms. Small quantities of copper can be tolerated by humans; however, excessive dosage and long-term exposure may cause imbalance in cellular processes.…”
Section: Introductionmentioning
confidence: 99%
“…27,28 Our group has successfully used this program for calculating the stability constants for copper complexes of a new thio Schiff base. 29 The best fits to the spectrophotometric data show that two complexes for Cu 2+ ion, were obtained, these being CuL (ε = 1. Figure 2c, and 2f).…”
Section: Study Of Complexation Between Bhah Ligand and Metal Ionsmentioning
confidence: 91%
“…7B inset). [44][45][46][47][48][49] Interference tests Interestingly, the calibration curve no longer obeys the static quenching rule based on Poisson statistics, 43 that the Cu 2+ concentration is proportional to the ECL signal not its inverse value (Fig.…”
Section: Quantication Of Ecl Sensor and Analytical Performancementioning
confidence: 99%