Construction and Test of a Gradient System for NMR Diffusion Studies in Interface Systems

Abstract: Für NMR‐Diffusionsmessungen wurde ein z‐Gradientensystem zur Erzeugung intensiver Feldgradientenimpulse überarbeitet. Dazu wurde das Gradientenfeld einer aktiv abgeschirmten Spule mittels der Finite‐Elemente‐Methode optimiert. Das System wurde aus Glaskeramik als Spulenträger aufgebaut. Es besitzt kein 1H‐NMR‐Eigensignal und weist einen hohen Strom/Gradienten‐Wandlerfaktor von 0,37 T m–1A–1 auf. Mit dem Nachweis isotroper und anisotroper Diffusion in wässrigen Lösungen eines PEO‐PPO‐PEO Triblock‐Copolymers und… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 28 publications
0
6
0
Order By: Relevance
“…Magnetic field gradient pulses in conventional PFG NMR can today be operated with values above 20 T/m. Schlayer et al [31], e.g., achieved a value of 37 T/m with a 100 A power supply. The design with two gradient coils on the top and on the bottom of the MAS stator of a Bruker probe reaches about 0.5 T/m with a 10 A power supply.…”
Section: Methodsmentioning
confidence: 99%
“…Magnetic field gradient pulses in conventional PFG NMR can today be operated with values above 20 T/m. Schlayer et al [31], e.g., achieved a value of 37 T/m with a 100 A power supply. The design with two gradient coils on the top and on the bottom of the MAS stator of a Bruker probe reaches about 0.5 T/m with a 10 A power supply.…”
Section: Methodsmentioning
confidence: 99%
“…8 The self-diffusion coefficient D of water at a temperature of 303 K is D = 2.594 × 10 −9 m 2 s −1 . 49 The gradient strength obtained at 100% gradient intensity is 0.54 T m −1 for the MAS PFG NMR probe (AVANCE 750, 10 A gradient current supply) and 21 T m −1 for the static PFG NMR probe PK3 50 on AVANCE 400 (60 A gradient current supply). PK3 50 is a low-power homemade probe with a nutation frequency of 20 kHz for 1 H measurements.…”
Section: Methodsmentioning
confidence: 99%
“…The gradient strength obtained at 100% gradient intensity is 0.54 T m –1 for the MAS PFG NMR probe (AVANCE 750, 10 A gradient current supply) and 21 T m –1 for the static PFG NMR probe PK3 on AVANCE 400 (60 A gradient current supply). PK3 is a low-power homemade probe with a nutation frequency of 20 kHz for 1 H measurements. The repetition delay was always longer than the fivefold of the longitudinal relaxation time.…”
Section: Methodsmentioning
confidence: 99%
“…All NMR experiments were performed at 3T on a custom‐built 125 MHz FEGRIS‐NT spectrometer, which achieves a maximum gradient amplitude of Gitalicmax = 35 T/m along the direction of the main magnetic field . The dimensions of the shielded gradient coil and the saddle‐type RF coil were optimized for a 10 mm sample height inside a 7 mm NMR tube . The sample temperature was controlled and monitored within ΔT = 0.1°C (0.1 K) using an evaporated nitrogen stream and a built‐in heater/thermometer regulation system.…”
Section: Methodsmentioning
confidence: 99%
“…55,56 The dimensions of the shielded gradient coil and the saddle-type RF coil were optimized for a 10 mm sample height inside a 7 mm NMR tube. 57 The sample temperature was controlled and monitored within ΔT = 0.1°C (0.1 K) using an evaporated nitrogen stream and a built-in heater/thermometer regulation system. The initial temperature was set to T = +20°C (293 K) and decreased to 0°C (273 K) in steps of 2°C (2 K).…”
Section: Nmr Acquisitionsmentioning
confidence: 99%