1998
DOI: 10.1016/s0003-2670(98)00412-7
|View full text |Cite
|
Sign up to set email alerts
|

Constraints, iteration schemes and convergence criteria for concentration calculations in X-ray fluorescence spectrometry with the use of fundamental parameter methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0
2

Year Published

1999
1999
2017
2017

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 16 publications
(16 citation statements)
references
References 22 publications
0
7
0
2
Order By: Relevance
“…In SBR the AN groups of NBR 33 are replaced by an aromatic styrene group. Bulky side groups, like styrene, give rise to increased chain stiffness attributed to steric hindrance 19, 25. This is also visible in an increase in glass‐transition temperature (−52°C) and a decrease in gas permeability ( P C2H4 = 18.9 Barrer) compared to those of BR ( T g = −91°C, P C2H4 = 129.9 Barrer).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In SBR the AN groups of NBR 33 are replaced by an aromatic styrene group. Bulky side groups, like styrene, give rise to increased chain stiffness attributed to steric hindrance 19, 25. This is also visible in an increase in glass‐transition temperature (−52°C) and a decrease in gas permeability ( P C2H4 = 18.9 Barrer) compared to those of BR ( T g = −91°C, P C2H4 = 129.9 Barrer).…”
Section: Resultsmentioning
confidence: 99%
“…The apparatus was calibrated using a single‐point calibration method and the data of the sample were corrected for the influence of the polymer matrix material. The apparatus used was a Philips PW 1480 X‐ray spectrometer and the data were analyzed using a fundamental parameter method 19…”
Section: Methodsmentioning
confidence: 99%
“…The qualitative investigations of chemical composition were performed in the mapping system of the internal part of mould halves, and by analysing characteristic elements: Cu, Sn, Pb, As, Sb, Ni. [22][23][24]. The 3D model acquisition was performed with a triangulation based 3D laser scanner (MetraSCAN 3D), using an optical tracking system (C-Track 780) by Creaform.…”
Section: Issues and Research Methodologymentioning
confidence: 99%
“…The test is usually based on pure element calibration method (i.e. Fundamental Parameter method) [14][15][16], which allows for performing standard-free measurements by using spectral library.…”
Section: Introductionmentioning
confidence: 99%