Constitutive models and failure properties of fibrous tissues of carotid artery atheroma based on their uniaxial testing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 39 publications
0
4
0
Order By: Relevance
“…The potential of full-field methods is especially important for diseased soft tissues such as atherosclerotic arteries, the heterogeneity of which disables creation of a regular specimen shape. [11,[49][50][51] In addition to material non-homogeneity, a high variation may result from non-uniform specimen thickness violating the needed assumptions of the test [52] ; also these errors can be decreased by using the proposed IR approach.…”
Section: Discussionmentioning
confidence: 99%
“…The potential of full-field methods is especially important for diseased soft tissues such as atherosclerotic arteries, the heterogeneity of which disables creation of a regular specimen shape. [11,[49][50][51] In addition to material non-homogeneity, a high variation may result from non-uniform specimen thickness violating the needed assumptions of the test [52] ; also these errors can be decreased by using the proposed IR approach.…”
Section: Discussionmentioning
confidence: 99%
“…Each ring was cut axially and the created specimen was clamped in a tensile tester (Camea s.r.o., Czech Republic). A pre-load of 0.01 N was applied to straighten the specimen (in saline bath at 37 °C) and then load was increased till rupture (Lisický et al, 2021).…”
Section: Mechanical Testingmentioning
confidence: 99%
“…Here the knowledge of geometry, loading conditions and material characteristics is crucial. Various mechanical tests such as uniaxial (Lisický et al, 2021) or equibiaxial (Polzer et al, 2015). (Cunnane et al, 2016), or inflation tests (Sommer et al, 2010) are used to obtain artery wall response.…”
Section: Introductionmentioning
confidence: 99%
“…The sample thickness was measured by dial indicator (MarCator 1075, produced by Mahr, Germany, accuracy 0.01 mm, pin diameter 4.1 mm) at 5 locations of each specimen; the mean value is used for further analysis. After clamping a pre-tension of 0.1 N was applied to each specimen to ensure its flatness (Lisický, 2021). The testing is displacement controlled; three different displacement speeds…”
Section: Testing and Evaluationmentioning
confidence: 99%