2019
DOI: 10.1109/temc.2018.2869987
|View full text |Cite
|
Sign up to set email alerts
|

Consistency Test of Ion-Flow Density Measurement System Using an Improved Gray Relational Analysis Method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
2
2
1

Relationship

2
3

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 30 publications
0
3
0
Order By: Relevance
“…where is the radius of the conductors, is the relative air density, is the surface roughness, generally between 0.4 and 0.6, and is the correction factor of humidity. The corona inception electric field near the wires in the harsh weather is 12.82kV/cm by equation (12). According to the curve in figure 4(b), for the UHVDC transmission lines whose voltage is less than or equal to 1000kV, the radius can be selected within 280mm.…”
Section: Adaptability Of Detection Device In Uhv Electric Fieldsmentioning
confidence: 99%
See 1 more Smart Citation
“…where is the radius of the conductors, is the relative air density, is the surface roughness, generally between 0.4 and 0.6, and is the correction factor of humidity. The corona inception electric field near the wires in the harsh weather is 12.82kV/cm by equation (12). According to the curve in figure 4(b), for the UHVDC transmission lines whose voltage is less than or equal to 1000kV, the radius can be selected within 280mm.…”
Section: Adaptability Of Detection Device In Uhv Electric Fieldsmentioning
confidence: 99%
“…Audible noise, especially its high-frequency components, will be greatly attenuated when it propagates over long distances in the medium [6]. Due to the existence of charge distribution areas with different concentrations near the transmission line, which is quite different from the air medium, the audio parameter characteristics of the audible noise during the propagation process will also change [12]. Even in the laboratory environment, due to the limitation of the insulation safety distance, the measuring point is still far away from the sound source [13].…”
Section: Introductionmentioning
confidence: 99%
“…With the large-scale implementations of HVDC transmission lines, the environmental impacts due to electromagnetic field have become a focus of public attention in the following technical parameters: electric field, ion current density, space charge density, radio interference, audible noise, etc. [6]- [9].…”
Section: Introductionmentioning
confidence: 99%