2012
DOI: 10.1021/ac203471y
|View full text |Cite
|
Sign up to set email alerts
|

Consensus Structure Elucidation Combining GC/EI-MS, Structure Generation, and Calculated Properties

Abstract: This article explores consensus structure elucidation on the basis of GC/EI-MS, structure generation, and calculated properties for unknown compounds. Candidate structures were generated using the molecular formula and substructure information obtained from GC/EI-MS spectra. Calculated properties were then used to score candidates according to a consensus approach, rather than filtering or exclusion. Two mass spectral match calculations (MOLGEN-MS and MetFrag), retention behavior (Lee retention index/boiling p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
69
0

Year Published

2013
2013
2016
2016

Publication Types

Select...
9
1

Relationship

5
5

Authors

Journals

citations
Cited by 63 publications
(70 citation statements)
references
References 30 publications
1
69
0
Order By: Relevance
“…Above 80 % (50 of 60, 81 of 96) of the target compounds that were in STOFF-IDENT were also within the calculated log D range using the RTI standards. While the majority of substances matched, the non-match of 10 and 15 manually validated target substances (per participant, respectively) shows that a consensus approach should be considered when using retention time prediction approaches [70].…”
Section: Retention Time Information In Lc-hrmsmentioning
confidence: 99%
“…Above 80 % (50 of 60, 81 of 96) of the target compounds that were in STOFF-IDENT were also within the calculated log D range using the RTI standards. While the majority of substances matched, the non-match of 10 and 15 manually validated target substances (per participant, respectively) shows that a consensus approach should be considered when using retention time prediction approaches [70].…”
Section: Retention Time Information In Lc-hrmsmentioning
confidence: 99%
“…As shown for GC-EI-MS the involvement of mass spectral substructure information and calculated properties may be effective in limiting the generated structures to a manageable number. 43 In this study, insufficient information from fragmentation patterns was available to limit the number of candidates sufficiently. This can be demonstrated for Peak 17 (SI Table S4), where the occurrence of only one fragment corresponding to a loss of carbonyl ([M+H-CO] + ) results in the generation of more than 10 000 000 possible structures for the formula C 20 H 9 N 3 O 2 .…”
Section: Ionization Of Standard Compounds By Esi and Apcimentioning
confidence: 99%
“…(B) Degradation of TBBPA derivatives predicted by UM-PPS. spectrometry characterization, and battery software applications should become the new trends for the identification of unknown metabolites or TBBPA/S and their derivatives in environmental matrices [59].…”
Section: Perspectivesmentioning
confidence: 99%