Connection requirements for wind farms: A survey on technical requierements and regulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
73
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 157 publications
(77 citation statements)
references
References 6 publications
0
73
0
Order By: Relevance
“…Current controllers are designed to control positive and negative sequences of the rotor current on the basic of machine models in positive and negative d-q reference frames in order to achieve four targets such as: the balance of stator current, constant output active power, invariant electromagnetic torque for reducing the mechanical stress, and oscillation of the rotor current [4]. In detail, both positive and negative sequence components are used in this scheme.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations
“…Current controllers are designed to control positive and negative sequences of the rotor current on the basic of machine models in positive and negative d-q reference frames in order to achieve four targets such as: the balance of stator current, constant output active power, invariant electromagnetic torque for reducing the mechanical stress, and oscillation of the rotor current [4]. In detail, both positive and negative sequence components are used in this scheme.…”
Section: Introductionmentioning
confidence: 99%
“…The stator voltage's magnitude is determined by the exchange of reactive power between generator and the grid while the phase difference is controlled by active power [4]. Therefore, power balance must be maintained on the grid.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Although the use of variable-speed wind turbines with power electronic interfaces is the current trend, many directly connected induction-generator-based wind turbines are still in operation. All wind turbine technologies, irrespective of type, employed in high-power wind farms, are required by new grid codes in some countries to have a fault ridethrough capability for faults on the transmission system [2]. To deal with this situation, flexible AC transmission system (FACTS) devices (such as a STATCOM) can be used.…”
Section: Introductionmentioning