2016
DOI: 10.1021/acs.jpcb.5b11841
|View full text |Cite
|
Sign up to set email alerts
|

Connection of Jones and Mueller Tensors in Second Harmonic Generation and Multi-Photon Fluorescence Measurements

Abstract: Despite the rapidly growing use of second harmonic generation (SHG) and two-photon excited fluorescence (TPEF) microscopy, opportunities for relating polarization-dependent measurements back to local structure and molecular orientation are often confounded by losses in polarization purity. In this work, connections linking Mueller tensor and Jones tensor descriptions of polarization-dependent SHG and TPEF are shown to substantially simplify partially depolarized microscopy measurements. These connections were … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
14
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 18 publications
(14 citation statements)
references
References 63 publications
(133 reference statements)
0
14
0
Order By: Relevance
“…However, a large number of observables with many different incident polarization states are required in order to populate all 36 unique elements of the super-Mueller matrix. In a recent complementary framework [17], the Mueller tensors in partially depolarizing assemblies were greatly simplified by directly bridging Jones and Mueller tensors. The role of partial depolarization can in principle be incorporated by a single additional adjustable parameter relative to analogous measurements in nondepolarizing assemblies.…”
mentioning
confidence: 99%
See 3 more Smart Citations
“…However, a large number of observables with many different incident polarization states are required in order to populate all 36 unique elements of the super-Mueller matrix. In a recent complementary framework [17], the Mueller tensors in partially depolarizing assemblies were greatly simplified by directly bridging Jones and Mueller tensors. The role of partial depolarization can in principle be incorporated by a single additional adjustable parameter relative to analogous measurements in nondepolarizing assemblies.…”
mentioning
confidence: 99%
“…In a model system, predictions from a mathematical framework connecting Jones and Mueller tensors [17] were compared with observations for z -cut quartz. With this framework in place, polarization-dependent SHG from partial or complete depolarization of the incident beam can be quantitatively described using the intuitive Jones tensor.…”
mentioning
confidence: 99%
See 2 more Smart Citations
“…Later, Simpson J G developed a formalism for nonlinear optical ellipsometry using Jones matrices. 34, 35 4 Â 1 Stokes vector and 4 Â 4 Mueller matrix are used [36][37][38][39] in second harmonic generation (SHG) microscopy to understand molecular level structure of biological materials. SHG is studied recently using Double Stokes-Double Mueller Matrix formalism by di®erent groups.…”
Section: Introductionmentioning
confidence: 99%