2016
DOI: 10.1016/j.jcsr.2016.07.025
|View full text |Cite
|
Sign up to set email alerts
|

Connection of I-beam to box-column by a short stub beam

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
7
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 26 publications
(7 citation statements)
references
References 9 publications
0
7
0
Order By: Relevance
“…After that, research on steel structure beam-to-column connections has been extensively carried out. Among them, the reduced beam section moment connections and the reinforced moment connections are both moved outwardly through plastic hinges, using sacrificial yielding at beam ends to dissipate dynamic response energy (Han et al, 2011;Sherven and Maryam, 2012;Tsavdaridis et al, 2012;Erfani et al, 2016;Liu et al, 2017;Shi et al, 2017). However, repairing the plastic damage in steel beams results in the disruption of the building function and expensive repair costs (Qu et al, 2017;Chen.…”
Section: Introductionmentioning
confidence: 99%
“…After that, research on steel structure beam-to-column connections has been extensively carried out. Among them, the reduced beam section moment connections and the reinforced moment connections are both moved outwardly through plastic hinges, using sacrificial yielding at beam ends to dissipate dynamic response energy (Han et al, 2011;Sherven and Maryam, 2012;Tsavdaridis et al, 2012;Erfani et al, 2016;Liu et al, 2017;Shi et al, 2017). However, repairing the plastic damage in steel beams results in the disruption of the building function and expensive repair costs (Qu et al, 2017;Chen.…”
Section: Introductionmentioning
confidence: 99%
“…Connection of HSS column is one of the most critical challenging components of HSS structural system. In recent years several HSS column-beam connection has been evaluated, new hybrid connections have also been suggested [1][2][3][4][5][6][7].…”
Section: Introductionmentioning
confidence: 99%
“…The obtained results indicated that the connection reduces contribution of the beam to the moment strength creating a ductile fuse far from components of the beam-to-column connection. A numerical study was performed by [16] to solve inaccessibility to the inside of box-columns for assembling the continuity plates. The results showed that connections with short stub beam enhance the behavior of connection and the continuity plates can be omitted and AISC seismic provisions requirements being satisfied.…”
Section: Introductionmentioning
confidence: 99%