1987
DOI: 10.1021/bi00392a024
|View full text |Cite
|
Sign up to set email alerts
|

Conformational aspects and rotational dynamics of synthetic adrenocorticotropin-(1-24) and glucagon in reverse micelles

Abstract: The tryptophan (Trp) rotational dynamics and the secondary structure of the peptide hormones adrenocorticotropin-(1-24) [ACTH(1-24)]--the fully active N-terminal fragment of adrenocorticotropin-(1-39)--and glucagon were studied in aqueous solutions and in reverse micelles of sodium bis(2-ethylhexyl) sulfosuccinate (AOT)/water/isooctane, a system selected to mimic the membrane-water interface. In aqueous solutions, the total fluorescence intensity decays of their single Trp residue [Trp-9 and Trp-25 for ACTH(1-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
38
1

Year Published

1990
1990
2008
2008

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 40 publications
(41 citation statements)
references
References 50 publications
2
38
1
Order By: Relevance
“…Reverse micelles were prepared as previously described (45). Briefly, reverse micelles of AOT and water in isooctane were prepared with 0.1 M AOT and the desired amount of water.…”
Section: Methodsmentioning
confidence: 99%
“…Reverse micelles were prepared as previously described (45). Briefly, reverse micelles of AOT and water in isooctane were prepared with 0.1 M AOT and the desired amount of water.…”
Section: Methodsmentioning
confidence: 99%
“…Corrected emission spectra were recorded on a Hitachi F4010 spectrofluorometer, using excitation at 280 nm. Excitation and emission bandwidths of ( 5 , I S ) , (5,5 ) and (3,5 ) nm were used to measure wavelength at emission maximum and bandwidth, quantum yield and steady-state anisotropy, respectively. Peptide-free micellar solutions of appropriate wo were used as reference blanks in all absorption and emission measurements, Quantum yield of thc peptide (+, , ) in aqueous and reverse micellar solutions was determined relative to that of a solution of ~-T r p at pH 7.0 ($Trp.…”
Section: Methodsmentioning
confidence: 99%
“…Because lipid oxidative stress is a well established cause of cell damage, [37] we were interested to test the reporting capabilities of the two redox sensors in a lipid-like environment. To mimic lipid membranes, micelles dispersed in water have been used widely, [38] seeing as they can encapsulate organic molecules in the hydrophobic core. The two compounds, BD-PQ and BD-PHQ, are totally insoluble in water.…”
Section: Spectroelectrochemical and Chemical Fluorescence Switchingmentioning
confidence: 99%