“…The grid current i is connected with the inverters output current i csi by (3), whereas (4) shows the relation between the harmonics of the capacitor voltage and the CSI output current space phasor.…”
Section: B Passive Network Behaviourmentioning
confidence: 99%
See 1 more Smart Citation
“…The grid current i is connected with the inverters output current i csi by (3), whereas (4) shows the relation between the harmonics of the capacitor voltage and the CSI output current space phasor.…”
Section: B Passive Network Behaviourmentioning
confidence: 99%
“…(2,-2,0) Topological the five level inverter could for example be achieved by paralleling two three level inverters [3]. In operation one then must assure, that both inverters provide the same direct current.…”
Section: Multilevel Current Source Invertersmentioning
confidence: 99%
“…The multilevel CSC topologies are based on the principle of current clamping using inductors. All the available multilevel CSC topologies have been derived from their corresponding equivalent multilevel VSC topologies using the duality principle [9]. In the following, the discussion presented focuses mostly on the multilevel VSC topologies.…”
Section: Fig 23 Power Level Of Statcomsmentioning
confidence: 99%
“…A VSC and an equivalent CSC are considered to be a pair of dual structures. The multilevel CSC topologies are derived from the dual transform of the corresponding multilevel VSC topologies [9]. In the following sub-section, the dual CSC configuration of DCMC is described.…”
Section: Disadvantagesmentioning
confidence: 99%
“…This topology streamlines the necessity of isolated DC sources in the parallel H-bridge multilevel CSI. An alternate circuit design of multilevel CSI is made by using a multi-cell arrangement of multilevel CSI [13]- [15], which is the double flying capacitor multilevel VSI. Various control, strategies have been exhibited to control the voltage at intermediate levels and highlighted in [16]- [18].…”
Section: Introductionmentioning