2021
DOI: 10.1016/j.jvs.2021.05.026
|View full text |Cite
|
Sign up to set email alerts
|

Conformability of the GORE EXCLUDER iliac branch endoprosthesis is associated with freedom from adverse iliac events

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 27 publications
0
2
0
Order By: Relevance
“…Probable causes for these early complications have been attributed to severe tortuosity and lack of anatomic conformability in a recent detailed morphologic study, and these findings need further exploration in larger datasets with multiple devices. 20 To this point, DeRoo and colleagues (2021) performed an anatomic analysis of failures in the IBE 12-04 study and found that smaller internal iliac artery diameter and iliac tortuosity were predictors of adverse iliac events. 20 They found the IBE device to be very conformable to tortuous iliac anatomy, as was also reported by Della Schiava and colleagues (2016).…”
Section: J O U R N a L P R E -P R O O F 13mentioning
confidence: 99%
See 1 more Smart Citation
“…Probable causes for these early complications have been attributed to severe tortuosity and lack of anatomic conformability in a recent detailed morphologic study, and these findings need further exploration in larger datasets with multiple devices. 20 To this point, DeRoo and colleagues (2021) performed an anatomic analysis of failures in the IBE 12-04 study and found that smaller internal iliac artery diameter and iliac tortuosity were predictors of adverse iliac events. 20 They found the IBE device to be very conformable to tortuous iliac anatomy, as was also reported by Della Schiava and colleagues (2016).…”
Section: J O U R N a L P R E -P R O O F 13mentioning
confidence: 99%
“…20 To this point, DeRoo and colleagues (2021) performed an anatomic analysis of failures in the IBE 12-04 study and found that smaller internal iliac artery diameter and iliac tortuosity were predictors of adverse iliac events. 20 They found the IBE device to be very conformable to tortuous iliac anatomy, as was also reported by Della Schiava and colleagues (2016). 21 However, cases with excessive iliac tortuosity that resulted in non-conformability of the device to the anatomy were significantly associated with a higher incidence of occlusions and endoleaks.…”
Section: J O U R N a L P R E -P R O O F 13mentioning
confidence: 99%