Cellular Imaging Techniques for Neuroscience and Beyond 2012
DOI: 10.1016/b978-0-12-385872-6.00001-5
|View full text |Cite
|
Sign up to set email alerts
|

Confocal Laser Scanning: of Instrument, Computer Processing, and Men

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 25 publications
0
4
0
Order By: Relevance
“…We adapted an objective method ( Wouterlood et al. 2008 ; Beliën and Wouterlood 2012 ; Kooijmans et al. 2014 ) to count cell bodies ( Fig.…”
Section: Methodsmentioning
confidence: 99%
“…We adapted an objective method ( Wouterlood et al. 2008 ; Beliën and Wouterlood 2012 ; Kooijmans et al. 2014 ) to count cell bodies ( Fig.…”
Section: Methodsmentioning
confidence: 99%
“…After threshold analysis, we conducted voxel matrix analysis (SCIL_Image, TNO, Delft, The Netherlands). Scripts were used to instruct the software to determine whether conspicuous pairs of boutons and 3D objects fulfilled criteria to be counted as “contacts” (Beliën & Wouterlood, ). Briefly, structure A defined by its voxel matrix (matrix A, e.g., a bouton recorded in one channel of the confocal instrument) was considered to be in apposition with structure B (e.g., a dendrite recorded in a complementary channel in the confocal instrument and defined by voxel matrix B) if a minimum of 100 voxels overlap was reported by the software of the involved voxel matrices (A) and (B).…”
Section: Methodsmentioning
confidence: 99%
“…Briefly, structure A defined by its voxel matrix (matrix A, e.g., a bouton recorded in one channel of the confocal instrument) was considered to be in apposition with structure B (e.g., a dendrite recorded in a complementary channel in the confocal instrument and defined by voxel matrix B) if a minimum of 100 voxels overlap was reported by the software of the involved voxel matrices (A) and (B). This criterion is extensively discussed in Beliën and Wouterlood () and in Wouterlood and Beliën (). Also for colocalization of fluorescence signal in structures, a quantitative criterion was applied: “colocalization” was reported by the software if a minimum of 200 voxels of the voxel matrix of a 3D object (e.g., a bouton) recorded in one channel in the confocal instrument coincided with the voxel matrix belonging to a 3D object scanned in a complementary channel (e.g., an aggregate of VGAT signal).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation