Confirmatory identification of sixteen non‐steroidal anti‐inflammatory drug residues in raw milk by liquid chromatography coupled with ion trap mass spectrometry

Abstract: The European Council Decision 2002/657/EC established that group B substances detected in foods must be identified and confirmed on the basis of their molecular structure. To this aim, we have developed a panel of methods for unambiguous determination of sixteen non-steroidal anti-inflammatory drugs (NSAIDs) in cattle and buffalo raw milk. A multi-residue reversed-phase high-performance liquid chromatography method with photodiode array detection is described for quantitative screening analysis. For confirmato… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
22
0

Year Published

2008
2008
2020
2020

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 53 publications
(23 citation statements)
references
References 12 publications
1
22
0
Order By: Relevance
“…A Thermo Accela UHPLC system coupled to a Maylab Switch column manager and to the Q-Exactive mass spectrometer was used. The chromatographic system was coupled to the MS with a heated electrospray ionization source II (HESI II (12,70). Total runtime was 12 min.…”
Section: Lc-q-orbitrap-hrms/msmentioning
confidence: 99%
See 3 more Smart Citations
“…A Thermo Accela UHPLC system coupled to a Maylab Switch column manager and to the Q-Exactive mass spectrometer was used. The chromatographic system was coupled to the MS with a heated electrospray ionization source II (HESI II (12,70). Total runtime was 12 min.…”
Section: Lc-q-orbitrap-hrms/msmentioning
confidence: 99%
“…Acetonitrile, the effect of which on protein precipitation facilitates efficient extraction, is the most widely used solvent [4][5][6]11]. However, methanol [7] as well as acetonitrile/methanol [12] or acetonitrile/ethyl acetate mixtures [9] are also employed, and good overall recovery values have been reported for all systems. A controversial issue concerning the extraction step is the addition of ascorbic acid to prevent oxidation of pyrazolones (e.g., phenylbutazone and oxyphenbutazone [11,12].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…2,3,[6][7][8][9][10][11][12][13][14] Microemulsion electrokinetic chromatography (MEEKC), which has a similar separation mechanism as micellar electrokinetic chromatography (MEKC), has been demonstrated to be a reliable separation technique for a wide range of analytes, including NSAIDs compounds. [15][16][17][18][19][20][21] For all CE derived techniques, including MEKC and MEEKC, on-capillary UV detection is still employed as the major detection mode.…”
Section: Introductionmentioning