CONCORD: comparison of cosmic radiation detectors in the radiation field at aviation altitudes

Abstract: Space weather can strongly affect the complex radiation field at aviation altitudes. The assessment of the corresponding radiation exposure of aircrew and passengers has been a challenging task as well as a legal obligation in the European Union for many years. The response of several radiation measuring instruments operated by different European research groups during joint measuring flights was investigated in the framework of the CONCORD (COmparisoN of COsmic Radiation Detectors) campaign in the radiation f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
26
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 26 publications
(27 citation statements)
references
References 28 publications
1
26
0
Order By: Relevance
“…During the return flight on 15 September 2015, the measured dose rates were (1.43 ± 0.15) μGy/h and (4.73 ± 0.37) μSv/h, respectively, which is significantly lower due to the greater atmospheric shielding at FL340. The measured dose rates complement recently published results performed with the same detectors for comparable solar modulation ( W ≈ 66) at different cutoff rigidities and altitudes [ Meier et al, ].…”
Section: Resultssupporting
confidence: 85%
See 3 more Smart Citations
“…During the return flight on 15 September 2015, the measured dose rates were (1.43 ± 0.15) μGy/h and (4.73 ± 0.37) μSv/h, respectively, which is significantly lower due to the greater atmospheric shielding at FL340. The measured dose rates complement recently published results performed with the same detectors for comparable solar modulation ( W ≈ 66) at different cutoff rigidities and altitudes [ Meier et al, ].…”
Section: Resultssupporting
confidence: 85%
“…The sensitive volume of the HAWK 2 (TEPC) is a 4.95 inches diameter plastic sphere that is filled with a tissue equivalent gas consisting of 99.7% propane at a pressure of about 7 torr [ Conroy , ], simulating a cell size of 2 µm. The HAWK 2 instrument is also sensitive to indirectly ionizing particles, e.g., neutrons [ Meier et al, ]. The measured rates of absorbed dose in silicon d D Si / d t and ambient dose equivalent d H*(10)/ d t with their uncertainties are given in Table .…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The survey of reports about correspondingly dedicated flight missions in different scientific journals revealed three potential sources of measuring data for the comparison with model calculations, namely, the Coordinated Access to Aircraft for Transnational Environmental Research (CAATER) flight campaign (Lillhök et al, ), the Comparison of Airborne RAdiation Measuring Equipment for implementation of Legal requirements (CARAMEL) campaign (Wissmann et al, ), and the COmparisoN of COsmic Radiation Detectors (CONCORD) campaign (Meier et al, ). The interested reader is referred to the corresponding references for more detailed information.…”
Section: Sources Of Measuring Datamentioning
confidence: 99%