2023
DOI: 10.1186/s43074-023-00094-4
|View full text |Cite
|
Sign up to set email alerts
|

Conceptual design of the optical system of the 6.5m wide field multiplexed survey telescope with excellent image quality

Abstract: Astrophysics and cosmology in the coming decades urgently need a large field-of-view (FOV), highly multiplexed spectroscopic survey telescope satisfying challenging image quality and stability requirements. The 6.5 m MUltiplexed Survey Telescope (MUST) proposed by Tsinghua University will be constructed on the Saishiteng Mountain of Northwest China to improve the spectroscopic survey capability of ground-based optical telescopes. In this paper, we demonstrate the conceptual design of the optical system of MUST… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 11 publications
(2 citation statements)
references
References 21 publications
0
1
0
Order By: Relevance
“…Ray tracing simulations are widely used to design, optimize and analyze optical systems. Its applications are diverse, ranging from designing spectrometers (Naeem et al, 2022) or telescopes (Zhang et al, 2023), to understanding the optics of the human eye (Hong et al, 2011;Simpson, 2020;van Vught et al, 2022). Moreover, in ophthalmology, ray tracing is used to optimize the outcomes of cataract surgery (Artal et al, 2023;Canovas & Artal, 2011) and evaluate the accuracy of ocular radiotherapy (Jaarsma-Coes et al, 2023).…”
Section: Statement Of Needmentioning
confidence: 99%
“…Ray tracing simulations are widely used to design, optimize and analyze optical systems. Its applications are diverse, ranging from designing spectrometers (Naeem et al, 2022) or telescopes (Zhang et al, 2023), to understanding the optics of the human eye (Hong et al, 2011;Simpson, 2020;van Vught et al, 2022). Moreover, in ophthalmology, ray tracing is used to optimize the outcomes of cataract surgery (Artal et al, 2023;Canovas & Artal, 2011) and evaluate the accuracy of ocular radiotherapy (Jaarsma-Coes et al, 2023).…”
Section: Statement Of Needmentioning
confidence: 99%
“…Combined with the setting of other parameters, the simulation image under different parameters can be obtained. At the same time, the area corresponding to 80% energy of the diffraction spot (called EE80) is selected as the evaluation standard [43], and the quality of the image can be assessed quantitatively.…”
Section: Imaging Simulation Of Sub-eye Aperturementioning
confidence: 99%