2020
DOI: 10.5185/amlett.2020.061531
|View full text |Cite
|
Sign up to set email alerts
|

Conceptual Design of the CSP Lead Demonstrator SOLEAD

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
3
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 9 publications
0
3
0
Order By: Relevance
“…Within the framework of the H2020 project NEXTOWER, a Pb-based demonstrator SOLEAD was designed to be integrated into a 100 kW CSP plant that used air as the heat transfer fluid in the thermal receiver in 2020. The concept is a one-tank direct heat storage configuration with two integrated heat exchangers using liquid Pb as the storage medium at temperatures from 600 C to 750 C. 28 The storage tank was 1.2 m in diameter and 3.6 m in height. Complementary material tests of 800H steel with an FeCrAl coating in liquid Pb at 800 C showed sufficient resistance against the liquid metal.…”
Section: Heavy Liquid Metal Basedmentioning
confidence: 99%
“…Within the framework of the H2020 project NEXTOWER, a Pb-based demonstrator SOLEAD was designed to be integrated into a 100 kW CSP plant that used air as the heat transfer fluid in the thermal receiver in 2020. The concept is a one-tank direct heat storage configuration with two integrated heat exchangers using liquid Pb as the storage medium at temperatures from 600 C to 750 C. 28 The storage tank was 1.2 m in diameter and 3.6 m in height. Complementary material tests of 800H steel with an FeCrAl coating in liquid Pb at 800 C showed sufficient resistance against the liquid metal.…”
Section: Heavy Liquid Metal Basedmentioning
confidence: 99%
“…Piazza et al [16] report on the design of a liquid lead storage tank with temperatures of 600-750 • C in the frame of the EU project NEXTOWER (concentrating solar tower application). The material used was Alloy 800 with an internal cladding of FeCrAl, which showed good resistance against the liquid metal at 800 • C [17].…”
Section: Introductionmentioning
confidence: 99%
“…Sodium, for example, is liquid between 98 and 883 • C (1 bar) and the eutectic mixture of lead and bismuth (LBE) is liquid between 125 and 1533 • C (1 bar) [7,8]. Therefore, they have been proposed as heat transfer fluids in concentrating solar power plants [9,10,5,11] and also for the use in thermal energy storage systems [12,13,14,15].…”
Section: Introductionmentioning
confidence: 99%