2009
DOI: 10.1088/1674-1137/33/s2/033
|View full text |Cite
|
Sign up to set email alerts
|

Conceptual design of Hefei advanced light source

Abstract: The conceptual of Hefei Advanced Light Source, which is an advanced VUV and Soft X-ray source, was developed at NSRL of USTC. According to the synchrotron radiation user requirements and the trends of SR source development, some accelerator-based schemes were considered and compared; furthermore storage ring with ultra low emittance was adopted as the baseline scheme of HALS. To achieve ultra low emittance, some focusing structures were studied and optimized in the lattice design. Compromising of emittance, on… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 4 publications
(4 reference statements)
0
3
0
Order By: Relevance
“…In the future, it will be used as an external reference for the comparison of the accuracy of the laser tracker and geometric leveling with the help of the hydrostatic leveling system at the site of Hefei Advanced Light Facility (HALF) [22,23]. Furthermore, the deformation prediction algorithm research is carried out based on years of particle accelerators' control network re-measurement data.…”
Section: Discussionmentioning
confidence: 99%
“…In the future, it will be used as an external reference for the comparison of the accuracy of the laser tracker and geometric leveling with the help of the hydrostatic leveling system at the site of Hefei Advanced Light Facility (HALF) [22,23]. Furthermore, the deformation prediction algorithm research is carried out based on years of particle accelerators' control network re-measurement data.…”
Section: Discussionmentioning
confidence: 99%
“…These effects need to be minimized to improve the performance of storage rings. For example, the dynamic aperture shrinkage caused by the sextupole field errors cannot be ignored in advanced third-generation light sources, future-ring based colliders and ultimate storage rings [1][2][3][4][5][6][7][8], where the nonlinear performance is very sensitive to the errors. So the work of the optimization of magnet sorting is in high demand for installation of magnets during the construction of a storage ring.…”
Section: Introductionmentioning
confidence: 99%
“…Table 1 gives the main parameters of HALS. More detailed descriptions can be found in our other publications [1][2][3] . HALS's emittance will be less than 0.2 nm•rad after the damping wiggles are installed.…”
Section: Introductionmentioning
confidence: 99%