2013
DOI: 10.1016/j.electacta.2013.07.101
|View full text |Cite
|
Sign up to set email alerts
|

Concentration and electrode material dependence of the voltammetric response of iodide on platinum, glassy carbon and boron-doped diamond in the room temperature ionic liquid 1-ethyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
43
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 24 publications
(49 citation statements)
references
References 50 publications
6
43
0
Order By: Relevance
“…52 Influence of I − anion concentration on the electrooxidation kinetics at Pt, glassy carbon and boron doped diamond electrodes in EMIm bis(trifluoromethanesulfonyl)imide has been demonstrated. 53 Two electrooxidation peaks and the stability constant of I 3 − 10 −4 M −1 for EMImI, NaI etc. systems has been calculated for 1-buthyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide at Pt microelectrode.…”
Section: Resultsmentioning
confidence: 99%
“…52 Influence of I − anion concentration on the electrooxidation kinetics at Pt, glassy carbon and boron doped diamond electrodes in EMIm bis(trifluoromethanesulfonyl)imide has been demonstrated. 53 Two electrooxidation peaks and the stability constant of I 3 − 10 −4 M −1 for EMImI, NaI etc. systems has been calculated for 1-buthyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide at Pt microelectrode.…”
Section: Resultsmentioning
confidence: 99%
“…The electro-oxidation behavior of iodide ions has also been studied in several solvents [17,18]. There is a single oxidation peak for various solvents such as water, methanol and acetic acid [19,20].…”
Section: Introductionmentioning
confidence: 99%
“…On glassy carbon, even though the I − /I 3 − plateau is not as well defined, the two processes still convincingly exhibit a 2:1 ratio, strongly suggesting that the overall iodide oxidation processes are analogous on both electrode materials. The diffusion coefficient of iodide is estimated to be 2.68 × 10 -7 cm 2 s −1 and 2.61 × 10 −7 cm 2 s −1 from the background subtracted M L plateaus on platinum and glassy carbon, respectively, in excellent agreement with each other and with the literature value of 2.68 × 10 −7 cm 2 s −1 [53,57]. This study clearly demonstrates that the information available from the semiintegrated M-E data is superior to that available from the unprocessed I-E data, further expanding upon the electroanalytical utility of cyclic voltammetry.…”
Section: Electro-oxidation Of Iodide On a Glassy Carbon Electrode In mentioning
confidence: 75%
“…The discussions below pertain to the I − /I 3 − /I 2 redox processes in RTILs, a subject which has led to significant research interest in recent years [1,53,[57][58][59][60][61][62][63][64] due to the integral role that the I − /I 3 − process plays in the operation of dye-sensitized solar cells (DSSCs). A DSSC, in essence, has three fundamental components: a semiconductor photoanode (TiO 2 ) with an adhered photoactive dye, a platinized cathode (counter electrode), and an electrolyte containing a suitable redox shuttle.…”
Section: Electro-oxidation Of Iodide On a Glassy Carbon Electrode In mentioning
confidence: 99%
See 1 more Smart Citation