Computerized MRS voxel registration and partial volume effects in single voxel 1H-MRS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
17
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(18 citation statements)
references
References 60 publications
1
17
0
Order By: Relevance
“…Of particular note is the need to specify the order of multiple voxel rotations (which do not commute) for voxels. A range of voxel overlaps have been shown previously, from 57% within-subject for a small (15 mm) 3 parietal voxel [7] to 86% for a slightly larger (20 mm) 3 posterior cingulate voxel [17]. There is some evidence that automated voxel placement protocols, which typically calculate voxel location parameters from parameters co-registering images to standard space within-session, can perform as well as human operators and remove some variance [17], and prospective voxel placement correction has been demonstrated with a navigator-based acquisition [18].…”
Section: Discussionmentioning
confidence: 81%
See 2 more Smart Citations
“…Of particular note is the need to specify the order of multiple voxel rotations (which do not commute) for voxels. A range of voxel overlaps have been shown previously, from 57% within-subject for a small (15 mm) 3 parietal voxel [7] to 86% for a slightly larger (20 mm) 3 posterior cingulate voxel [17]. There is some evidence that automated voxel placement protocols, which typically calculate voxel location parameters from parameters co-registering images to standard space within-session, can perform as well as human operators and remove some variance [17], and prospective voxel placement correction has been demonstrated with a navigator-based acquisition [18].…”
Section: Discussionmentioning
confidence: 81%
“…It is therefore somewhat surprising that the fidelity of voxel placement has only occasionally been investigated in the literature [7] [17]. In order to evaluate the repeatability of voxel placement for MEGA-PRESS GABA scans, this study calculated the DOC both within-subject and, after image co-registration, between-subject.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Voxel placement was performed by an operator who was blinded to the drug condition and drug condition was randomized to eliminate bias in voxel placement based on drug condition. Achieved voxel overlap (64%) did not differ between conditions and is on the order of that achieved by automated voxel placement [91], indicating excellent and stable within-subject reliability of voxel placement. Physiological data confirmed sympathomimetic drug activity, providing evidence of internal validity.…”
Section: Strengths and Limitationsmentioning
confidence: 81%
“…However, a relatively large voxel in MRSI may compromise gray matter (GM) and white matter (WM) or cerebral spinal fluid (CSF). Therefore, to report the concentrations in a standardized metabolite concentration unit, the partial volume effect and the relaxation effect must be considered . An additional nonwater suppression (NWS) scan, using the same experiment parameters, is necessary to obtain an unsuppressed water signal for calibration.…”
Section: Introductionmentioning
confidence: 99%