2002
DOI: 10.1007/s00791-002-0082-8
|View full text |Cite
|
Sign up to set email alerts
|

Computer simulations of cardiac defibrillation: a look inside the heart

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
85
0

Year Published

2002
2002
2012
2012

Publication Types

Select...
3
3

Relationship

1
5

Authors

Journals

citations
Cited by 102 publications
(87 citation statements)
references
References 53 publications
2
85
0
Order By: Relevance
“…Local activation and repolarisation times and APD were measured during the 7th paced beat, at a basic cycle length of 250 ms. In addition, to better study arrhythmogenesis in the rabbit ventricles, the dynamics of the scroll-wave filaments, the organising centres of re-entrant activity, was analysed using an algorithm published previously (Trayanova et al, 2002;Larson et al, 2003). Pseudoelectrocardiograms (ECG) (Plonsey and Barr, 2000), were computed at a node marked E2 in Fig.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Local activation and repolarisation times and APD were measured during the 7th paced beat, at a basic cycle length of 250 ms. In addition, to better study arrhythmogenesis in the rabbit ventricles, the dynamics of the scroll-wave filaments, the organising centres of re-entrant activity, was analysed using an algorithm published previously (Trayanova et al, 2002;Larson et al, 2003). Pseudoelectrocardiograms (ECG) (Plonsey and Barr, 2000), were computed at a node marked E2 in Fig.…”
Section: Discussionmentioning
confidence: 99%
“…This study used a 3D geometrically accurate rabbit ventricular model (Vetter and McCulloch, 1998) that incorporated realistic fibre architecture and representation of the blood within the ventricular cavities and the perfusing bath (Trayanova et al, 2002). The finite element mesh consisted of 829 021 tetrahedral elements, with a spatial resolution of 500 μm.…”
Section: Computational Modelmentioning
confidence: 99%
See 2 more Smart Citations
“…The model is the first to use bi-domain simulation (in which the electrical field outside the cells is reconstructed as well as the potentials across the cell membranes), with detailed fibre geometry and detailed cellular electrophysiology. (61,62) Such simulations require enormous computing resources, currently available only on large supercomputers (which is the main reason why the simulation is restricted to a slice of the ventricle-computations of the whole canine ventricle would, at present, be too demanding).…”
Section: Calcium Balance: the Hilgemann-noble Modelmentioning