2018
DOI: 10.1002/elps.201800113
|View full text |Cite
|
Sign up to set email alerts
|

Computer simulation of the enantioselective separation of weak bases in an online capillary electrophoresis based microanalysis configuration comprising sulfated cyclodextrin as selector

Abstract: Computer simulation was utilized to characterize the electrophoretic processes occurring after reactant mixing in an online assay format used for monitoring the enantioselective N-demethylation of ketamine to norketamine in the presence of highly sulfated γ-cyclodextrin (HS-γ-CD). The incubated reaction mixture (at pH 7.4 and without chiral selector) is bracketed by a low pH BGE containing 2% HS-γ-CD as chiral selector, thereby forming a discontinuous buffer system. Upon power application, simulation provides … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5

Relationship

5
0

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 18 publications
0
8
0
Order By: Relevance
“…Furthermore, in discontinuous buffer systems properties affecting complexation, including the ionic strength, vary along the separation column (Fig. and ) and the impact of ionic strength on complexation is not considered by the simulator used in our work. The influence of the complexation parameters on the methadone zone formation was investigated by simulation using different input values for complexation.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Furthermore, in discontinuous buffer systems properties affecting complexation, including the ionic strength, vary along the separation column (Fig. and ) and the impact of ionic strength on complexation is not considered by the simulator used in our work. The influence of the complexation parameters on the methadone zone formation was investigated by simulation using different input values for complexation.…”
Section: Resultsmentioning
confidence: 99%
“…with an apparent complexation constant K and a mobility of the formed complex u c (Table 1). This approach was successfully used previously in our work with S-␤-CD and the enantiomers of methadone [18], ketamine [29] and norketamine [29]. In this work methadone enantiomer separations were effected with S-␤-CD lot 03711JA, a multiple isomer S-␤-CD with 7-11 sulfated groups per CD.…”
Section: Treatment and Input Constants For The Multiple Isomer Mixturmentioning
confidence: 98%
“…The conductivity of the incubation mixture is much higher compared to the conductivity of the BGE. Simulation efforts provided insight into the diffusional mixing of the reactants and buffer constituents [61] and, upon power application, into the formation of moving boundaries and new zones [61,101]. In this…”
Section: Assessment Of Drug Metabolism and Inhibition In Vitromentioning
confidence: 99%
“…In this system, the analytes first migrate cationically in a zone electrophoretic manner until they come in contact with the negatively charged chiral selector. Complexation of the analytes has a focusing effect, reverses the electrophoretic transport of the analytes and enables enantioseparation [101].…”
Section: Applicationsmentioning
confidence: 99%
“…SIMUL5complex was used to elucidate the impact of the complexation of buffer constituents with neutral agents on common buffer properties and analyte and system peaks in CZE , and to provide insight into the sweeping process of a drug in presence of a neutral CD . Furthermore, the fundamentals of field‐amplified electrokinetic injection of cations for enantioselective CZE with sulfated β‐cyclodextrin (S‐β‐CD) , the characterization of isomer mixtures of S‐β‐CD , the investigation of the enantioselective separation of weak bases in an on‐line CZE microanalysis configuration comprising S‐β‐CD as selector , and the exploration of inverse cationic ITP for separation of methadone enantiomers with S‐β‐CD as chiral selector were also studied with this simulator. The MEKC behavior of neutral analytes in presence of SDS and the comparison of transient trapping with sweeping in MEKC with SDS were investigated with GENTRANS.…”
Section: Introductionmentioning
confidence: 99%