2004
DOI: 10.1016/s0169-2607(03)00081-6
|View full text |Cite
|
Sign up to set email alerts
|

Computer programs to facilitate the estimation of time-dependent drug effects on ion channels

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2005
2005
2014
2014

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 7 publications
0
6
0
Order By: Relevance
“…Currents were sampled at 1 kHz and filtered at 333 Hz. Data acquisition and analysis were done with Pulse + Pulsefit (HEKA electronik, Lambrecht, Germany), Igor Pro [28] (Wavemetrics Inc., Lake Oswego, OR, USA), Prism and Instat Demo version (Graphpad Software Inc., San Diego, CA, USA; free at www.graphpad.com) software. Data were shown as mean ± standard error to the mean.…”
Section: Electrophysiologymentioning
confidence: 99%
“…Currents were sampled at 1 kHz and filtered at 333 Hz. Data acquisition and analysis were done with Pulse + Pulsefit (HEKA electronik, Lambrecht, Germany), Igor Pro [28] (Wavemetrics Inc., Lake Oswego, OR, USA), Prism and Instat Demo version (Graphpad Software Inc., San Diego, CA, USA; free at www.graphpad.com) software. Data were shown as mean ± standard error to the mean.…”
Section: Electrophysiologymentioning
confidence: 99%
“…Current signals were amplified and digitized by an EPC-9 patch clamp amplifier, stored, and analyzed with Pulse/Pulsefit software (HEKA), DataAccess (Bruxton), and Igor Pro (Wavemetrics). 10 In all experiments, 87% to 90% series resistance compensation was achieved. After establishing the whole-cell configuration and waiting 5 min for equilibration, the stimulation protocol was continuously applied (identical double-step protocol as that described above) every 15 s, and rundown was corrected.…”
Section: Beerse Protocolmentioning
confidence: 99%
“…After establishing the whole-cell configuration and waiting 5 min for equilibration, the stimulation protocol was continuously applied (identical double-step protocol as that described above) every 15 s, and rundown was corrected. 10 Cells were continuously perfused by either control or drug-containing extracellular solution. The effect of compound was evaluated after 5 min of drug application.…”
Section: Beerse Protocolmentioning
confidence: 99%
“…Some 3rd-party analysis packages are able to import pClamp files directly for analysis of data recorded in pClamp 9 suite, such as Origin, SigmaPlot [6], and DataView [7]. Marrannes and Prins [8] also designed IVOC and IROC programs to facilitate the analysis of drug effects on currents through ion channels in the cell membrane measured by means of voltage clamp. The programs are written in Igor Pro (WaveMetrics) and read exported files or raw data files generated by the PULSE (HEKA Electronic) or pClamp (Axon Instruments) systems.…”
Section: Introductionmentioning
confidence: 99%
“…Differing from some earlier studies such as IVOC and IROC [8], which programmed in Igor Pro, we designed a novel class module to directly read the raw data files recorded from HEKA instruments without any other program support (such as Igor Pro and Origin). We have preprocessed the raw data by using PCDReader in our previous patch clamp experiments, such as [9][10][11].…”
Section: Introductionmentioning