2002
DOI: 10.1002/apj.5500100612
|View full text |Cite
|
Sign up to set email alerts
|

Computer‐aided Measurement of Vapour‐Liquid Equilibria in a Dynamic Still at Sub‐Atmospheric Pressures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
11
0

Year Published

2003
2003
2018
2018

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(13 citation statements)
references
References 26 publications
2
11
0
Order By: Relevance
“…This pressure transmitter has a pressure range of 0 to 1 bar. This is in line with the maximum pressure limit of 101 kPa, for the dynamic recirculating glass still of Joseph et al , The combined standard uncertainty, U ( p ), in the pressure measurement was estimated to be 0.1 kPa.…”
Section: Experimental Sectionsupporting
confidence: 84%
See 2 more Smart Citations
“…This pressure transmitter has a pressure range of 0 to 1 bar. This is in line with the maximum pressure limit of 101 kPa, for the dynamic recirculating glass still of Joseph et al , The combined standard uncertainty, U ( p ), in the pressure measurement was estimated to be 0.1 kPa.…”
Section: Experimental Sectionsupporting
confidence: 84%
“…The VLE measurements were undertaken using a low pressure glass recirculating still that is described in previous publications. , The VLE stills have been used extensively for low-pressure phase equilibria measurements in the Thermodynamics Research Unit at the University of KwaZulu-Natal. The schematic diagram, description of the apparatus, as well as the experimental procedure are available in the previous publication. , …”
Section: Experimental Sectionmentioning
confidence: 99%
See 1 more Smart Citation
“…The apparatus used for VLE measurements was a dynamic glass type apparatus that has been used extensively in our group and described previously by Joseph et al , The operating procedure used was that of Joseph et al , A schematic of the setup is shown in Figure . The apparatus operates similarly to a packed distillation column operating under total reflux.…”
Section: Methodsmentioning
confidence: 99%
“…The VLE measurements were conducted using a dynamic-analytical glass apparatus available in our laboratories. The equipment is a replica of that presented by Joseph et al; , however, temperature is controlled manually and has been used in our group for many years. Temperature was measured using a Pt-100 temperature probe.…”
Section: Methodsmentioning
confidence: 99%