2018
DOI: 10.1007/s13246-018-0645-8
|View full text |Cite
|
Sign up to set email alerts
|

Computed tomography imaging with the Adaptive Statistical Iterative Reconstruction (ASIR) algorithm: dependence of image quality on the blending level of reconstruction

Abstract: Computed tomography (CT) is a useful and widely employed imaging technique, which represents the largest source of population exposure to ionizing radiation in industrialized countries. Adaptive Statistical Iterative Reconstruction (ASIR) is an iterative reconstruction algorithm with the potential to allow reduction of radiation exposure while preserving diagnostic information. The aim of this phantom study was to assess the performance of ASIR, in terms of a number of image quality indices, when different rec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
11
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
3
2
1

Relationship

1
5

Authors

Journals

citations
Cited by 15 publications
(13 citation statements)
references
References 35 publications
1
11
0
1
Order By: Relevance
“…In our study, ADMIRE 5 resulted in improved SNR and lower noise in comparison to ADMIRE 1 and 3 with the same radiation dose, which confirms results from previous studies 13,36 . Although the ADMIRE strength of 5 possibly had a higher amount of noise reduction, blocky appearance (losing detail in the image) of higher strength IR 30,37 was not observed in our study, which may due to ADMIRE’s excellent noise reduction potential, the technology adopts a "statistical model" and iterative decoding chip to integrate the statistical data of virtual data domain, image domain, and model domain efficiently 38 . Through multiple iterations, the artifact was removed and the noise was reduced to achieve real‐time high‐definition iterative imaging 38 .…”
Section: Discussionsupporting
confidence: 88%
“…In our study, ADMIRE 5 resulted in improved SNR and lower noise in comparison to ADMIRE 1 and 3 with the same radiation dose, which confirms results from previous studies 13,36 . Although the ADMIRE strength of 5 possibly had a higher amount of noise reduction, blocky appearance (losing detail in the image) of higher strength IR 30,37 was not observed in our study, which may due to ADMIRE’s excellent noise reduction potential, the technology adopts a "statistical model" and iterative decoding chip to integrate the statistical data of virtual data domain, image domain, and model domain efficiently 38 . Through multiple iterations, the artifact was removed and the noise was reduced to achieve real‐time high‐definition iterative imaging 38 .…”
Section: Discussionsupporting
confidence: 88%
“…Lack of familiarity of the image appearance might cause missing diagnoses, since the radiologist might misinterpret manifestations or structures, which appear different with different IR levels or vendors. The optimal IR level might differ between different types of CT examinations and should be evaluated when establishing a standard protocol [ 20 ]. In our study, objective image quality increased significantly with higher levels of IR due to the decreasing image noise (Fig.…”
Section: Discussionmentioning
confidence: 99%
“…Because the higher radiation dose in PMCT results in less image noise compared to clinical routine CT, optimal IR levels for noise suppression may differ between PMCT and clinical CT examinations. Further, the IR level specifically needs to be evaluated for different PMCT protocols (e.g., PMCT of the coronary arteries) in terms of quantitative and qualitative image quality [ 20 ]. For this purpose, we aimed to investigate the impact of different levels of IR on the objective and subjective image quality in PMCTA.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, particular attention should be given to ensure that radiation dose variability is minimized in patients undergoing repeat CT examination [17]. Because of the strict correlation between image noise and radiation expo-sure, the iterative reconstruction approach has the potential to be employed with data acquired at lower radiation doses while preserving clinical information [18].…”
Section: Radiation Protectionmentioning
confidence: 99%