2014
DOI: 10.1007/s10554-014-0516-7
|View full text |Cite
|
Sign up to set email alerts
|

Computed tomography for planning and postoperative imaging of transvenous mitral annuloplasty: first experience in an animal model

Abstract: To investigate the use of computed tomography (CT) to measure the mitral valve annulus size before implantation of a percutaneous mitral valve annuloplasty device in an animal trial. Seven domestic pigs underwent CT before and after implantation of a Cardioband™ (a percutaneously implantable mitral valve annuloplasty device) with a second-generation 128-section dual-source CT machine. Implantation of the Cardioband™ was performed in a standard fashion according to a protocol. Animals were sacrificed afterwards… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 20 publications
(17 reference statements)
0
7
0
Order By: Relevance
“…One study investigated the use of computed tomography (CT) to measure mitral valve annulus size before implantation of a percutaneous mitral valve annuloplasty device in an animal trial. [80] Seven domestic pigs underwent CT before and after implantation of a Cardioband TM with a second-generation 128-section dualsource CT scanner. Implantation of the Cardioband TM was performed in a standard fashion.…”
Section: Computed Tomography Componentmentioning
confidence: 99%
“…One study investigated the use of computed tomography (CT) to measure mitral valve annulus size before implantation of a percutaneous mitral valve annuloplasty device in an animal trial. [80] Seven domestic pigs underwent CT before and after implantation of a Cardioband TM with a second-generation 128-section dualsource CT scanner. Implantation of the Cardioband TM was performed in a standard fashion.…”
Section: Computed Tomography Componentmentioning
confidence: 99%
“…As both scenarios have a negative impact on the informative value of the preclinical study results, appropriate annular measurements and prosthesis sizing are considered critical. A better understanding of cardiac morphometries, including the inter-species differences and intra-species anatomical variabilities, is thereby essential to improve safety and efficacy in non-clinical device evaluation [14][15][16] and to concurrently reduce the possibility of misleading and meaningless study results lacking transferability 35 .…”
Section: Discussionmentioning
confidence: 99%
“…High profile valves may also cause obstruction of the left ventricular outflow tract due to the geometric relationship between the aortic and the mitral valve 13 . Pre-procedural planning with modern imaging modalities such as trans-esophageal echocardiography and three-dimensional computed tomography (CT) have shown to lead to a better understanding of annular sizing and geometry and a reduction of these complications and have therefore become an integral part in the clinical assessment of patients 10,[14][15][16] .…”
mentioning
confidence: 99%
“…Individual decision for interventional direct annuloplasty as choice for TMVR was taken at the team's discretion respecting pathomechanism of MR and assessment of anatomical suitability for direct annuloplasty as well as other available forms of TMVR and approved by specialists of the manufacturing company. Anatomical feasibility was evaluated (and confirmed by experts of the manufacturing company) by a protocol of transesophageal echocardiography (TEE) and computed tomography (CT, for specifications of CT protocol in detail, see reference 12 ), which were also used for planning the procedure (e.g. planning fluoroscopic angulations, optimal height of trans-septal puncture and anchor implantation zones, and selection of the size of the device).…”
Section: Methodsmentioning
confidence: 99%