Computational Models for the Mechanical Investigation of Stomach Tissues and Structure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
14
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
1
1

Relationship

3
4

Authors

Journals

citations
Cited by 23 publications
(14 citation statements)
references
References 49 publications
0
14
0
Order By: Relevance
“…The local orientation of the i th fibers family was described by the unit vector a 0 i , assumed along the two principal directions of the reinforcing mesh. The definition of the strain energy function was the following: W(),Cbolda0ibolda0i=Wm()C+Wfi(),Cbolda0ibolda0i Wm()C=KvJ12+C1()Ifalse˜13 Wfi(),Cbolda0ibolda0i=[]C4i/α4i2{}exp[]α4i()I4i1α4i()I4i11 where Ifalse˜1 is the first iso‐volumetric invariant of the right Cauchy‐Green strain tensor, as Ifalse˜1=tr()J2/3boldC. The parameters K v and C 1 are related to bulk stiffness, as B = 2 K v , and shear modulus, as G = 2 C 1 , respectively.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The local orientation of the i th fibers family was described by the unit vector a 0 i , assumed along the two principal directions of the reinforcing mesh. The definition of the strain energy function was the following: W(),Cbolda0ibolda0i=Wm()C+Wfi(),Cbolda0ibolda0i Wm()C=KvJ12+C1()Ifalse˜13 Wfi(),Cbolda0ibolda0i=[]C4i/α4i2{}exp[]α4i()I4i1α4i()I4i11 where Ifalse˜1 is the first iso‐volumetric invariant of the right Cauchy‐Green strain tensor, as Ifalse˜1=tr()J2/3boldC. The parameters K v and C 1 are related to bulk stiffness, as B = 2 K v , and shear modulus, as G = 2 C 1 , respectively.…”
Section: Methodsmentioning
confidence: 99%
“…Each specimen was stretched up to a 60% strain according to a 60%/s constant strain rate . Finally, aiming to analyses the structural behavior, inflation tests were carried out on urethral tubular segments pertaining to both distal and proximal regions. A peristaltic pump (VerderFlex Vantage 5000, Verder Ltd, Castleford, UK) allowed the almost instantaneous inflation of the samples with saline up to a 2000% volumetric ratio.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A biomechanical model of the stomach was developed on the basis of coupled experimental and computational activities [ 5 , 32 ]. Experimentations were performed on samples from animal models, such as wastes from local abattoirs, and human surgical scraps from Padua University Hospital.…”
Section: In Silico Analysis Of Surgical Procedures: Case Studiesmentioning
confidence: 99%
“…Another structure-based model was presented for the first time for GI tissues by Natali and colleagues in their study of the individual layers of the esophagus [23] before being applied to the intact tissue and layers of the large intestine [24,25] as well as to the intact tissue of the stomach [83]. A list of studies that presented a Natali-type model is provided in Table S5.…”
mentioning
confidence: 99%