2014
DOI: 10.1007/s00246-014-1055-7
|View full text |Cite
|
Sign up to set email alerts
|

Computational Fluid Dynamics Characterization of Blood Flow in Central Aorta to Pulmonary Artery Connections: Importance of Shunt Angulation as a Determinant of Shear Stress-Induced Thrombosis

Abstract: The central aortic shunt, consisting of a Gore-Tex (polytetrafluoroethylene) tube (graft) connecting the ascending aorta to the pulmonary artery, is a palliative operation for neonates with cyanotic congenital heart disease. These tubes often have an extended length, and therefore must be angulated to complete the connection to the posterior pulmonary arteries. Thrombosis of the graft is not uncommon and can be life-threatening. We have shown that a viscous fluid (such as blood) traversing a curve or bend in a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
27
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 33 publications
(28 citation statements)
references
References 43 publications
1
27
0
Order By: Relevance
“…The simulated central shunts were constructed using a 3D modeling software computer package (Autodesk Inventor, San Rafael, CA, USA). Once the centerline of a shunt was determined from the angiogram, a constant-diameter, circular cross-section was swept along its course to form the tubular graft ( Figure 2, case 2; Figure 3, case 4) [29].…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The simulated central shunts were constructed using a 3D modeling software computer package (Autodesk Inventor, San Rafael, CA, USA). Once the centerline of a shunt was determined from the angiogram, a constant-diameter, circular cross-section was swept along its course to form the tubular graft ( Figure 2, case 2; Figure 3, case 4) [29].…”
Section: Methodsmentioning
confidence: 99%
“…The flow calculations were carried out using the CFD computer program Fluent 14.5 (Ansys, Inc., Lebanon, NH, USA), which solves the 3-D Navier-Stokes and continuity equations using the finite volume method [29,33] Computer simulation of an ascending aorta to main pulmonary artery shunt (blue) superimposed on the angiogram for case 2 (see Table 1). The shunt is 3. at the luminal wall.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…However, only a few of these studies have in vitro physical models to verify their numerical models [15][16][17][18][19][20][21][22]. The physical model of CABG is very valuable to assess the flow fields parameters practically.…”
Section: Introductionmentioning
confidence: 99%