2006
DOI: 10.1139/s05-023
|View full text |Cite
|
Sign up to set email alerts
|

Computational fluid dynamics application in modeling and improving the performance of a storage reservoir used as a contact chamber for microorganism inactivation

Abstract: This study explored the use of computational fluid dynamics (CFD) modeling approach to simulate two tracer studies conducted, in scaled-down physical models of an existing storage tank, to investigate the effect of tank configuration on the effective contact time (t 10 ). One of the scaled-down physical models, of the storage tank, was equipped with one baffle wall at the middle length and the other was equipped with nine baffle walls distributed evenly along the reservoir length. A comparison between the expe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
8
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 24 publications
0
8
0
Order By: Relevance
“…These have the shape of an S-curve when plotted with respect to time, with a minimum of 0 and a maximum of 1 (Templeton et al 2006). The FTC analysis investigates the effect of the rotational speed on the hydrodynamic flow characteristics (Ta 1999;Choi et al 2004;Baawain et al 2006;Svrcek et al 2006;Templeton et al 2006;Zhang 2006;Stamou 2008). Tracer testing is considered as a reliable approach for determining the hydraulic performance of a water treatment reactor (Svrcek et al 2006).…”
Section: Gridmentioning
confidence: 99%
See 2 more Smart Citations
“…These have the shape of an S-curve when plotted with respect to time, with a minimum of 0 and a maximum of 1 (Templeton et al 2006). The FTC analysis investigates the effect of the rotational speed on the hydrodynamic flow characteristics (Ta 1999;Choi et al 2004;Baawain et al 2006;Svrcek et al 2006;Templeton et al 2006;Zhang 2006;Stamou 2008). Tracer testing is considered as a reliable approach for determining the hydraulic performance of a water treatment reactor (Svrcek et al 2006).…”
Section: Gridmentioning
confidence: 99%
“…PHOENICS, ANSYS FLUENT, ANSYS CFX, FLOW3D, Flo + + and STAR-CD (Versteeg & Malalasekara 1995). In water and wastewater treatment processes, it has been widely used in investigation and optimization of plant design and operations (Haarhofi & Van der Walt 2001; Baawain et al 2006;Templeton et al 2006;Stamou 2008) and in flow distribution calculations in distribution channels (Ta 1999;Baek et al 2005). Using CFX multiphase modelling approach, Zhang et al (2008) could show for the flrst time that multiple sampling strategies are essential for improved ozone residual monitoring and tracer testing for full-scale ozone disinfection process.…”
Section: Cfd Modelling Proceduresmentioning
confidence: 99%
See 1 more Smart Citation
“…Until recently, contact tank design has used empirically derived equations, physical studies, and loosely descriptive tables (Wilson & Venayagamoorthy 2010, USEPA 2003). Advances in numerical methods and processing power have made computational fluid dynamics (CFD) an invaluable tool for understanding the complex flow phenomena that occur within disinfection contactors, but it is not widely used by small systems because of its cost and complexity (Amini et al 2011, Rauen et al 2008, Baawain et al 2006, Khan et al 2006). A majority of small systems still rely on empirical tables presented in USEPA's enhanced surface water treatment rules for determining disinfection (USEPA 2003).…”
mentioning
confidence: 99%
“…This unique wording by USEPA implies that plug flow may occur in both laminar and turbulent flow, despite the significant difference between these flows. Recent studies have shown that few systems achieve a uniform plug flow velocity field; however, those researchers studied only systems in which the flow regime was entirely turbulent (Amini et al, 2011; Zhang et al, 2011a; Zhang et al, 2011b; Baawain et al, 2006).…”
mentioning