Computational fluid dynamics analysis in a ribbed tube with different twisted tape inserts to enhance the heat transfer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 17 publications
0
2
0
Order By: Relevance
“…The main purpose of this comparison was to understand the rate of heat flow and temperature distribution along with the various length of the pipes. The study also observed that in the case of HLUTT and HLDTT tapes, there is a decrease in the thermal performance factor with an increase in Re and twisted ratios which are showing in Figure 4, whereas in the case of FLTT, the thermal performance factor tends to increase with different twisted ratios and improvements of Re [12]. Paneliya et al, [13] found 1.27 times larger heat transfer enhancement for X-Shaped tapes than twisted tape inserts by comparing the thermal characteristic of water flowing in a tube equipped with X-tape and twisted tape to investigate the effect of insert tape geometry on the heat exchanger tubes [13].…”
Section: Twisted Tape Insertsmentioning
confidence: 65%
See 1 more Smart Citation
“…The main purpose of this comparison was to understand the rate of heat flow and temperature distribution along with the various length of the pipes. The study also observed that in the case of HLUTT and HLDTT tapes, there is a decrease in the thermal performance factor with an increase in Re and twisted ratios which are showing in Figure 4, whereas in the case of FLTT, the thermal performance factor tends to increase with different twisted ratios and improvements of Re [12]. Paneliya et al, [13] found 1.27 times larger heat transfer enhancement for X-Shaped tapes than twisted tape inserts by comparing the thermal characteristic of water flowing in a tube equipped with X-tape and twisted tape to investigate the effect of insert tape geometry on the heat exchanger tubes [13].…”
Section: Twisted Tape Insertsmentioning
confidence: 65%
“…Another recent study of Gugulothu [12] has been conducted a CFD analysis to investigate the ribbed tube with different twisted tapes insert (FLTT, HLUTT, HLDTT) at uniform heat flux condition to sort out the performance characteristics of thermal efficiency, friction factor and mean Nusselt number. Air was treated as a working fluid and the simulations (Ansys Fluent) were carried out in a turbulent region by choosing suitable Re and found FTTT showed a better heat transfer, friction factor and enhancement efficiency compared to HLTT as a numerical result.…”
Section: Twisted Tape Insertsmentioning
confidence: 99%