2003
DOI: 10.1002/mrm.10552
|View full text |Cite
|
Sign up to set email alerts
|

Computation of the fractional anisotropy and mean diffusivity maps without tensor decoding and diagonalization: Theoretical analysis and validation

Abstract: Diffusion tensor MRI (DT-MRIKey words: magnetic resonance imaging; diffusion tensor encoding; fractional anisotropy; relative anisotropy; mean diffusivity; icosahedral encoding; Monte Carlo simulations Diffusion tensor MRI (DT-MRI) has become an increasingly important modality for understanding the organization of normal brain structures (1-4) and the evolution of neurological and psychiatric disorders (1,5-8). Currently, there are different methods for acquiring, processing, and modeling the measured DT-MRI d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
164
0

Year Published

2005
2005
2011
2011

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 112 publications
(169 citation statements)
references
References 37 publications
5
164
0
Order By: Relevance
“…al., 1995;Hasan and Narayana, 2003;Le Bihan, 1995;Pierpaoli et al, 1996). This problem is mitigated by the use of rotationally-invariant encoding schemes at high SNR as implemented in this paper.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…al., 1995;Hasan and Narayana, 2003;Le Bihan, 1995;Pierpaoli et al, 1996). This problem is mitigated by the use of rotationally-invariant encoding schemes at high SNR as implemented in this paper.…”
Section: Discussionmentioning
confidence: 99%
“…For example, the encoding scheme adopted in our work (Icosa21b) can provide independent rotationally-invariant data sets (Icosa6 and Icosa15) at different SNR values using the same data (Hasan and Narayana, 2003), and hence some sensitivity analysis can be conducted to show the SNR performance of this approach both regionally and globally. These studies will be reported in a future communication.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Due to the large number of diffusion directions evaluated, this sampling scheme was found to provide precise, rotationally-invariant parameter estimates when evaluated using simulated data (data not shown). For example, comparisons of the random direction sampling scheme with a 45 direction scheme based on icosahedral sampling (Batchelor et al, 2003;Hasan and Narayana, 2003) yielded extremely small differences in parameter estimates from simulated data (approximately one order of magnitude less than the uncertainty in the estimates). The diffusion-sensitizing gradient pulse length, d, was 5 ms.…”
Section: Methodsmentioning
confidence: 99%
“…The relationship between the measured diffusion signals using uniformly-distributed icosahedral tensor encoding schemes and the mean diffusivity can be expressed as [16][17][18]:…”
Section: Computation Of D Av and Ra N Using Icosahedral Schemesmentioning
confidence: 99%