2013
DOI: 10.1364/ol.38.003418
|View full text |Cite
|
Sign up to set email alerts
|

Compressive x-ray phase tomography based on the transport of intensity equation

Abstract: We develop and implement a compressive reconstruction method for tomographic recovery of refractive index distribution for weakly attenuating objects in a microfocus X-ray system. This is achieved through the development of a discretized operator modeling both the transport of intensity equation and X-ray transform that is suitable for iterative reconstruction techniques.Traditional tomography with hard X-rays recovers the attenuation of an object. Attenuation does not always provide good contrast when imaging… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
26
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
2

Relationship

3
6

Authors

Journals

citations
Cited by 47 publications
(28 citation statements)
references
References 21 publications
(35 reference statements)
0
26
0
Order By: Relevance
“…2D phase retrieval methods are easily combined with tomography [4][5][6][7][8][9][10][11][12], but when wave-optical effects become more prominent (as in microscopy), diffraction tomography [13][14][15][16][17][18][19] becomes necessary. All these methods require both angle scanning and multiple measurements at each angle, or a reference beam.…”
Section: Introductionmentioning
confidence: 99%
“…2D phase retrieval methods are easily combined with tomography [4][5][6][7][8][9][10][11][12], but when wave-optical effects become more prominent (as in microscopy), diffraction tomography [13][14][15][16][17][18][19] becomes necessary. All these methods require both angle scanning and multiple measurements at each angle, or a reference beam.…”
Section: Introductionmentioning
confidence: 99%
“…As a baseline, we solve the 2 regularized problem using ψ(L) = L 2 2 . In the experimental section, we also explore the use of two nonlinear regularizers for exploiting sparsity: 3D Total Variation (3DTV) regularization from Tian et al [39] and 1 regularization in the 2D wavelet domain, similar to Veeraraghavan et al [40]:…”
Section: Inverse Problemmentioning
confidence: 99%
“…In this work, a polycapillary optic was used to generate a sufficiently small secondary source from a large spot rotating anode Mo X-ray source by focusing through a pinhole. 14 Polycapillary optics are a collection of small hollow glass tubes through which X rays are guided as long as the incidence angle is less than the critical angle, as shown in Figure 5(b). The exiting beam is convergent to create a small, intense, secondary source of X rays.…”
Section: Introductionmentioning