1990
DOI: 10.1016/0021-9614(90)90143-e
|View full text |Cite
|
Sign up to set email alerts
|

Compression-factor measurements on ethane and (ethane + carbon dioxide) using a direct method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

1993
1993
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(7 citation statements)
references
References 14 publications
0
7
0
Order By: Relevance
“…The basic apparatus and recent modifications have been described previously (1,5) and the reported procedure has been followed here. The pressure change on mixing was measured on a differential pressure gauge (MKS Instruments Inc, Baratron model 315 BD Type 270B) with a claimed accuracy of 0.25 per cent of full scale.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The basic apparatus and recent modifications have been described previously (1,5) and the reported procedure has been followed here. The pressure change on mixing was measured on a differential pressure gauge (MKS Instruments Inc, Baratron model 315 BD Type 270B) with a claimed accuracy of 0.25 per cent of full scale.…”
Section: Methodsmentioning
confidence: 99%
“…This work is part of an ongoing study of gas mixtures of industrial importance. (1,2) Measurement of the pressure change on mixing of (0.5A + 0.5B)(g), initially at equal pressures p, allows calculation of the excess second virial coefficients o: (3) o = 2RTDp/{p 2 (1 + Dp/p)}.…”
Section: Introductionmentioning
confidence: 99%
“…The results are shown in (5) ) and for (ethane + carbon dioxide) (McElroy et al (4) ), although based on the same experimental results, are not extracted using the MHEMHS model and therefore differ in value from the coefficients in table 1. …”
Section: Virial Coefficients For Binary Mixturesmentioning
confidence: 94%
“…In past years, researchers from the University of Canterbury have experimentally found mixture third virial coefficients for all of these binaries using the direct method (McElroy et al, (3,4) McElroy and Ji Fang (5) ). These previous results were used with the MHEMHS model to calculate unlike-interaction third virial coefficients.…”
Section: Virial Coefficients For Binary Mixturesmentioning
confidence: 98%
“…The experimental apparatus used in this experimental study and the procedures were unchanged from those reported in earlier work (3,4). In order to extend the temperature range, a refrigeration system was coupled to the air thermostat.…”
Section: Methodsmentioning
confidence: 99%