2019
DOI: 10.1016/j.ejrad.2019.108667
|View full text |Cite
|
Sign up to set email alerts
|

Compressed SENSE accelerated 3D T1w black blood turbo spin echo versus 2D T1w turbo spin echo sequence in pituitary magnetic resonance imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
20
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 23 publications
(22 citation statements)
references
References 20 publications
2
20
0
Order By: Relevance
“…Three sequences had an identical geometric resolution (voxel size, 0.82 Â 0.82 Â 1.2 mm 3 ): first, the SENSE sequence using the SENSE PI technique (SENSE factor 2, scan duration, 5:08 minutes); second, the CS 3.5 sequence using the compressed SENSE acceleration technique with a variable density Poisson disk-sampling scheme followed by iterative reconstruction (compressed SENSE factor, 3.5; scan duration, 3:06 minutes) [18][19][20] ; and third, a spiral-TOF (abbreviated spiral) based on a stack of spirals with an in-plane spiral-out readout scheme (spiral interleaves, 27; spiral acquisition window, 10 milliseconds; scan duration, 1:32 minutes). In addition, 2 sequences with the same spiral-out readout scheme but higher resolution were acquired-the isotropic spiral-TOF 0.8 (abbreviated spiral 0.8) (voxel size, 0.80 Â 0.80 Â 0.80 mm 3 ;scan duration, 2:12 minutes) and the isotropic spiral-TOF 0.6 (abbreviated spiral 0.6) sequences (voxel size, 0.60 Â 0.60 Â 0.60 mm 3 ; scan duration, 5:22 minutes).…”
Section: Mr Imagingmentioning
confidence: 99%
“…Three sequences had an identical geometric resolution (voxel size, 0.82 Â 0.82 Â 1.2 mm 3 ): first, the SENSE sequence using the SENSE PI technique (SENSE factor 2, scan duration, 5:08 minutes); second, the CS 3.5 sequence using the compressed SENSE acceleration technique with a variable density Poisson disk-sampling scheme followed by iterative reconstruction (compressed SENSE factor, 3.5; scan duration, 3:06 minutes) [18][19][20] ; and third, a spiral-TOF (abbreviated spiral) based on a stack of spirals with an in-plane spiral-out readout scheme (spiral interleaves, 27; spiral acquisition window, 10 milliseconds; scan duration, 1:32 minutes). In addition, 2 sequences with the same spiral-out readout scheme but higher resolution were acquired-the isotropic spiral-TOF 0.8 (abbreviated spiral 0.8) (voxel size, 0.80 Â 0.80 Â 0.80 mm 3 ;scan duration, 2:12 minutes) and the isotropic spiral-TOF 0.6 (abbreviated spiral 0.6) sequences (voxel size, 0.60 Â 0.60 Â 0.60 mm 3 ; scan duration, 5:22 minutes).…”
Section: Mr Imagingmentioning
confidence: 99%
“…Compressed SENSE (CS) 10 is a recent clinical implementation of the combined compressed sensing and parallel imaging approach, which uses wavelet sparsity as compression transform and the SENSE model for parallel imaging. Compressed SENSE has been demonstrated to accelerate the acquisition of 2D and 3D images in a diagnostic setting [11][12][13][14][15] .…”
Section: Introductionmentioning
confidence: 99%
“…Certain limitations of this study should be acknowledged: Firstly, the sample size was quite small yet comparable to that of other studies assessing the clinical feasibility of sequences [1,19,21,22,30,31]. Specifically, due to the limited sample size, certain pathologies only appeared very rarely (i.e.…”
Section: Plos Onementioning
confidence: 83%
“…Two sequences had an identical geometric resolution (voxel size: 0.82 x 0.82 x 1.2 mm 3 ); First the Cartesian CS 3.5 sequence (used routinely at our and other institutions [9]) relying on the Compressed SENSE acceleration technique with a variable density Poisson disk-sampling scheme followed by iterative reconstruction (Compressed SENSE factor 3.5, scan duration 03:06 min). Details concerning the Compressed SENSE technique can be found elsewhere [13,19,20,21,22,23]. Second a prototypical non-Cartesian Spiral-TOF (abbreviated Spiral) based on a stack of spirals with an in-plane spiral-out readout scheme (spiral interleaves 27, spiral acquisition window 10 ms, scan duration 01:32 min).…”
Section: Mr Imagingmentioning
confidence: 99%
See 1 more Smart Citation