2011
DOI: 10.1007/s13361-011-0200-2
|View full text |Cite
|
Sign up to set email alerts
|

Comprehensive Two-Dimensional Separation of Hydroxylated Polybrominated Diphenyl Ethers by Ultra-Performance Liquid Chromatography Coupled with Ion Mobility-Mass Spectrometry

Abstract: A comprehensive two-dimensional system coupling ultra-performance liquid chromatography (UPLC) and ion mobility-mass spectrometry (IM-MS) has been applied for the separation and analysis of hydroxylated polybrominated diphenyl ethers (OH-PBDEs). A complex mixture containing 23 OH-PBDE congeners ranging from hydroxylated monobromodiphenyl ether (OHmonoBDE) to hydroxylated octabromodiphenyl ether (OH-octaBDE) was satisfactorily separated within 16 min of analysis time. The first-dimensional reversed-phase UPLC w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(10 citation statements)
references
References 48 publications
(53 reference statements)
0
10
0
Order By: Relevance
“…( a ) and ( b ) are reprinted with permission from Zhai et al (2014) Copyright (2014) American Chemical Society. ( c ) and ( d ) are reprinted with permission from Ma et al (2011) Copyright (2011) American Chemical Society. GC‐MS, gas chromatography–mass spectrometry; OH‐PBDE, hydroxylated polybrominated diphenyl ethers.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…( a ) and ( b ) are reprinted with permission from Zhai et al (2014) Copyright (2014) American Chemical Society. ( c ) and ( d ) are reprinted with permission from Ma et al (2011) Copyright (2011) American Chemical Society. GC‐MS, gas chromatography–mass spectrometry; OH‐PBDE, hydroxylated polybrominated diphenyl ethers.…”
Section: Methodsmentioning
confidence: 99%
“…Together with retention times and m / z values, the approach could improve the confidence in metabolite identification. Ma et al (2011) have developed a two‐dimensional LC‐IM‐MS for targeted analysis of OH‐PBDE congeners. The peak capacities and signal‐to‐noise ratios were significantly improved, background interference ions were substantially removed.…”
Section: Methodsmentioning
confidence: 99%
“…Following the preionization resolution in the first dimension, the second-dimensional IM-MS employed a hybrid electrospray quadrupole ion mobility time-of-flight mass spectrometer and added an extra postionization separation for between-class OH-PBDE congeners on account of their relative mobility disparity during a very short period of 8.8 ms. The two-dimensional separation plane also contributed to the removal of background interference ions and the enhanced confidence in the characterization of OH-PBDEs of interest [ 133 ].…”
Section: Instrumental Analysis Of Bfrsmentioning
confidence: 99%
“…Currently, LC in conjunction with ion mobility-mass spectrometry (IM-MS) is becoming increasingly popular for complex mixture analysis, due to complementary separation steps and elevated peak capacity. The applications include the analysis for environmental pollutants [38], rat urinary metabonome [39], human plasma proteome [40], peptide mixtures [41], pharmaceutical formulation [42], etc. The principle for IM-MS has been described in detail elsewhere [43].…”
Section: Introductionmentioning
confidence: 99%