2008
DOI: 10.1016/j.chroma.2007.11.101
|View full text |Cite
|
Sign up to set email alerts
|

Comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry peak sorting algorithm

Abstract: We report a novel peak sorting method for the two-dimensional gas chromatography/time-of-flight mass spectrometry (GC×GC/TOF-MS) system. The objective of peak sorting is to recognize peaks from the same metabolite occurring in different samples from thousands of peaks detected in the analytical procedure. The developed algorithm is based on the fact that the chromatographic peaks for a given analyte have similar retention times in all of the chromatograms. Raw instrument data are first processed by ChromaTOF (… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
43
0

Year Published

2008
2008
2020
2020

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 57 publications
(44 citation statements)
references
References 15 publications
1
43
0
Order By: Relevance
“…Recent advances in commercial instrumentation have decreased retention time shift. There have been many reports of retention time shift algorithms and peak alignment methods to correct retention time shift [48,[104][105][106]. Almstetter et al incorporated standards in each sample in order to adjust for retention time shifts in both dimensions [55,107].…”
Section: Fingerprintingmentioning
confidence: 99%
“…Recent advances in commercial instrumentation have decreased retention time shift. There have been many reports of retention time shift algorithms and peak alignment methods to correct retention time shift [48,[104][105][106]. Almstetter et al incorporated standards in each sample in order to adjust for retention time shifts in both dimensions [55,107].…”
Section: Fingerprintingmentioning
confidence: 99%
“…Analyzing human serum with GC ×GC-TOFMS, Oh et al [87] developed a peak sorting method to recognize peaks from the same metabolite in different chromatograms. Their algorithm used several search criteria with retention times and mass spectra, with options to eliminate non-target peaks.…”
Section: Peak Featuresmentioning
confidence: 99%
“…Usually, for a one-hour run, the raw data file size exceeds a few Gigabytes. Quite a number of algorithms have been published on alignment of peaks in such four-dimensional (first column retention time, second column retention time, mass, and intensity values) data (Kim et al, 2011;Oh et al, 2008;Pierce et al, 2005;Vial et al, 2009;Zhang, 2010), however only a few methods are available for a more complete typical preprocessing workflow. A compact overview of the available frameworks, their licenses and programming languages is given in Table 3.…”
Section: Framework For Gcxgc-ms Analysismentioning
confidence: 99%