2021
DOI: 10.1016/j.scitotenv.2020.141858
|View full text |Cite
|
Sign up to set email alerts
|

Comprehensive survey on radon mitigation and indoor air quality in energy efficient buildings from Romania

Abstract: This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
14
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 26 publications
(14 citation statements)
references
References 23 publications
0
14
0
Order By: Relevance
“…Through a graphical interface, ordinary users can observe the measurement results in the client, receive danger warnings and decision support suggestions. Burghele et al [24] used solid state nuclear track detectors to passively monitor radon and CO2 footprint in ten houses, and proposed personalized mitigation measures to meet residents' health and comfort needs.…”
Section: Related Workmentioning
confidence: 99%
“…Through a graphical interface, ordinary users can observe the measurement results in the client, receive danger warnings and decision support suggestions. Burghele et al [24] used solid state nuclear track detectors to passively monitor radon and CO2 footprint in ten houses, and proposed personalized mitigation measures to meet residents' health and comfort needs.…”
Section: Related Workmentioning
confidence: 99%
“…Airtightness of buildings has been negatively linked to indoor radon levels [ 23 ]. However, while centralized and decentralized mechanical supply and exhaust ventilation with heat recovery yielded a good efficiency in radon reduction, the best performance was confirmed to be based on subslab depressurization (SSD) [ 24 ]. The inconvenience of implementing SSD systems in inhabited houses is related to the cost and the disruption of daily household activities.…”
Section: Resultsmentioning
confidence: 99%
“…There were 11 exposure studies on radon [ 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 ] ( Table A1 ). Of these, 9 studies reported that energy efficiency thermal retrofitting in homes increased radon concentration [ 19 , 20 , 21 , 22 , 23 , 24 , 25 , 27 , 29 ].…”
Section: Resultsmentioning
confidence: 99%