1993
DOI: 10.1021/ac00065a004
|View full text |Cite
|
Sign up to set email alerts
|

Comprehensive supercritical fluid extraction/gas chromatographic analysis for organic compounds in soil matrices with an element-selective radiofrequency plasma detector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
6
0

Year Published

1995
1995
2007
2007

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 19 publications
(6 citation statements)
references
References 9 publications
0
6
0
Order By: Relevance
“…A description of the modulator and its use as an interface between SFE and GC have been recently published [8,10,12]. For these experiments the TDM was constructed from 8 cm of the front portion of the analytical column by repetitively coating that segment with automotive window defroster paint and drying with a heat gun until the resistance reached approximately 2.0 ohms.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A description of the modulator and its use as an interface between SFE and GC have been recently published [8,10,12]. For these experiments the TDM was constructed from 8 cm of the front portion of the analytical column by repetitively coating that segment with automotive window defroster paint and drying with a heat gun until the resistance reached approximately 2.0 ohms.…”
Section: Methodsmentioning
confidence: 99%
“…The benefit of eliminating interferences from co-eluting compounds is obtained by the use of selective detection for the analytes of interest. Wu et al used a radiofrequency plasma detector with an SFE/GC system for the selective detection of chlorine and sulfur in pesticide contaminated soil [12].…”
Section: Introductionmentioning
confidence: 99%
“…Supercritical fluid extraction, supercritical fluid chromatography, high-temperature capillary gas chromatography, and high-performance liquid chromatography address the issue of quantifying semivolatile and heavier hydrocarbons in petroleum products (Akhlaq, 1993;ASTM, 1984;DeAngelis, 1987;Di Sanzo and Yoder, 1991;George, 1994;King, 1989;Leazar, 1986;Lee, 1994;Levy etal, 1989;Lopez-Avila etal, 1992. McCormick et al, 1991Maynard and Michalik, 1988;Rhodes et al, 1991;Tong et al, 1993;Trestlano et al, 1985;Wu et al, 1993). Every method or protocol has its limitations, and these limitations must be defined so that its usefulness in a particular application can be ascertained.…”
Section: Introduction /mentioning
confidence: 99%
“…Therefore, in the present work, a 350 kHz helium plasma was utilized due to the straightforward energy coupling and because of the excellent analytical properties, as demonstrated for gas chromatographic detection. [24][25][26][27][28][29][30][31][32][33][34][35][36][37] To enhance the sensitivity of the method, the extraction solvent was evaporated prior to analysis. The solid sample was subsequently introduced at the plasma inlet by a sample probe.…”
mentioning
confidence: 99%
“…Microwaves have frequently been applied to sustain small helium plasmas, but the energy coupling is relatively complicated and requires the use of special cavities. Therefore, in the present work, a 350 kHz helium plasma was utilized due to the straightforward energy coupling and because of the excellent analytical properties, as demonstrated for gas chromatographic detection. To enhance the sensitivity of the method, the extraction solvent was evaporated prior to analysis. The solid sample was subsequently introduced at the plasma inlet by a sample probe.…”
mentioning
confidence: 99%