2022
DOI: 10.1016/j.foodchem.2022.133336
|View full text |Cite
|
Sign up to set email alerts
|

Comprehensive lipidomic analysis of milk polar lipids using ultraperformance supercritical fluid chromatography-mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 21 publications
(15 citation statements)
references
References 36 publications
1
11
0
Order By: Relevance
“…This result is different from that of Holstein milk [ 31 ], which may be related to the breed and feeding method.…”
Section: Resultsmentioning
confidence: 61%
“…This result is different from that of Holstein milk [ 31 ], which may be related to the breed and feeding method.…”
Section: Resultsmentioning
confidence: 61%
“…The Acquity UPSFC system (Waters, Milford, USA) was equipped with an HPLC pump and coupled to a Xevo G2-S Q-TOF-MS mass spectrometer, according to our previous study. 25 The results of the m / z values and fragment information with calculated extract masses were identified by using the software of Progenesis QI (Nonlinear Dynamics, Waters, Milford, MA, USA) equipped with two databases.…”
Section: Methodsmentioning
confidence: 99%
“…Phospholipids of human and cow's milk samples were extracted and purified by solid phase extraction following our previous study. 25 The phospholipids were separated from an Acquity UPC 2 ™ BEH Column (1.7 μm, 3 mm × 150 mm, Waters, Milford, USA) at 55 °C. The Acquity UPSFC system (Waters, Milford, USA) was equipped with an HPLC pump and coupled to a Xevo G2-S Q-TOF-MS mass spectrometer, according to our previous study.…”
Section: Phospholipid Compositions Analysismentioning
confidence: 99%
“…More recently, Jiang et al. [143] employed a novel method for the high‐throughput analysis of gangliosides in milk samples, using ultra‐performance supercritical fluid chromatography equipped with QTOF MS. In almost all previously described articles, standards of GM3 and GD3 were used.…”
Section: Milk Gangliosidesmentioning
confidence: 99%
“…More recently, modern techniques based on LC [127,128,142], HPLC [126], or UPLC [125,133,136] hyphenated to MS [125,126,129,142] or tandem MS [125,133,136,143] were used for their advantage of generating structural information on the ceramide moiety, polysaccharide chains and fatty acids. Hence, an LC MS/MS with a pneumatic ESI technique was developed and validated for the first time by Sørensen et al [127].…”
Section: Milk Gangliosidesmentioning
confidence: 99%