Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2018
DOI: 10.3390/environments5040043
|View full text |Cite
|
Sign up to set email alerts
|

Comprehensive Instrumental Odor Analysis Using SIFT-MS: A Case Study

Abstract: Instrumental analysis of odor is challenging due to the chemical diversity of many important odorants, the high sensitivity required to achieve human odor thresholds, and the dynamic nature of the odor itself. Conventional sensor-based and chromatographic technologies are poorly suited to the task. In this paper, we apply a novel direct mass spectrometric technique-selected ion flow tube mass spectrometry (SIFT-MS)-to the chemical analysis of odor. The SIFT-MS technique provides comprehensive real-time odor an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
6
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 33 publications
(57 reference statements)
0
6
0
Order By: Relevance
“…In general, a variety of methods are used to measure odors such as instrument analyzers like gas chromatographs, sensory devices like dynamic olfactometer, odor sensors or gas detection tubes. Additionally, new techniques for accurately evaluating odors have still been continuously developed [24][25][26][27][28][29][30][31][32][33].…”
Section: Correlation Between On-site Observed Odor Intensity and H 2 ...mentioning
confidence: 99%
“…In general, a variety of methods are used to measure odors such as instrument analyzers like gas chromatographs, sensory devices like dynamic olfactometer, odor sensors or gas detection tubes. Additionally, new techniques for accurately evaluating odors have still been continuously developed [24][25][26][27][28][29][30][31][32][33].…”
Section: Correlation Between On-site Observed Odor Intensity and H 2 ...mentioning
confidence: 99%
“…Selected ion flow tube mass spectrometry (SIFT-MS) was commercialized by Syft Technologies more recently than PTR-MS. SIFT-MS (Figure 1) has a potential advantage over PTR-MS due to its multiple, rapidly switchable chemical ionization agents (so called reagent or precursor ions) that detect diverse odor compounds with high selectivity [15,[17][18][19]. The SIFT-MS technique has been described in detail elsewhere [20,21].…”
Section: Introductionmentioning
confidence: 99%
“…A direct mass spectrometric technique, selected ion flow tube mass spectrometry (SIFT‐MS), can potentially address both sensory and safety concerns in one rapid analysis. The SIFT‐MS technique selectively and sensitively quantifies a wide range of volatiles (including most important odorants) in real time 9,10 . In its automated form, sample throughputs of 12 to more than 100 per hour have been demonstrated for headspace analysis, depending on the method 11,12…”
Section: Introductionmentioning
confidence: 99%