2019
DOI: 10.1016/j.ijhydene.2019.09.231
|View full text |Cite
|
Sign up to set email alerts
|

Comprehensive influences measurement and analysis of power converter low frequency current ripple on PEM fuel cell

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(11 citation statements)
references
References 23 publications
0
5
0
Order By: Relevance
“…The practical application of the multi-sine EIS technique is feasible, but the multi-sine technique requires a larger total amplitude than the single-sine technique. This may be a problem practically, as such an signal has similarities with ripple current originating in the power converter, which has been shown to lead to some degradation (Wahdame et al, 2008;Gerard et al, 2010;Zhan et al, 2019). Further studies are therefore necessary to verify that both techniques do not contribute significantly to degradation when run in a continual manner.…”
Section: Practical Application Of the Technique To Fuel Cell Stacksmentioning
confidence: 99%
“…The practical application of the multi-sine EIS technique is feasible, but the multi-sine technique requires a larger total amplitude than the single-sine technique. This may be a problem practically, as such an signal has similarities with ripple current originating in the power converter, which has been shown to lead to some degradation (Wahdame et al, 2008;Gerard et al, 2010;Zhan et al, 2019). Further studies are therefore necessary to verify that both techniques do not contribute significantly to degradation when run in a continual manner.…”
Section: Practical Application Of the Technique To Fuel Cell Stacksmentioning
confidence: 99%
“…By using a commercial power converter the output voltage is affected both by low and high-frequency ripple; it influences the current that suffers from the same distortion. Many works have been reported in the literature to investigate the effects of low and high-frequency current ripples on PEM FC stack [49][50][51][52], and more recently on alkaline EL [53,54]. In these relevant works, it has been demonstrated that low and high-frequency current ripple may affect the lifetime and performance of FC and EL during their operation.…”
Section: Dynamic Operation and Analysismentioning
confidence: 99%
“…12 Assume that there are no power losses in the UPS system. As the output voltage of 13 PEMFC could be considered as current control voltage source, the input current of an Consequently, the LFCR injected into the FC stack could bring about adverse effect on the voltage and current of FC, such as producing more heat, increasing the fuel consumption, reducing the output power and efficiency of FC, and impacting its availability [21].…”
Section: Equivalent Circuit Model Of Pemfc Stackmentioning
confidence: 99%